What absorbs at 671 cm⁻¹ in an FTIR spectrum?
A band near 671 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Risposta rapida
A band near 671 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Metal oxygen | 6 | 6 | 1,0 |
| Alkyl C-H | 3 | 3 | 1,0 |
| Aromatic ring | 2 | 2 | 1,0 |
| Ring structure | 2 | 2 | 1,0 |
| Silicon-oxygen (Si-O) | 2 | 2 | 1,0 |
| Silicon (Si) | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| N-O bond | 1 | 1 | 1,0 |
| Chlorine | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 0,9 |
| Sulfate (SO4) | 1 | 1 | 0,9 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 671 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Metal oxygen affidabilità 1,0
“The Sn-O stretching is observed at 671 for binary zinc tin”
Effect of annealing temperature on optical properties of binary zinc tin oxide nano-composite prepared by sol⠍gel route using simple precursors: Structural and optical studies by DRS, FT-IR, XRD, FESEM investigations DOI: 10.1016/j.saa.2014.08.031 -
Metal oxygen affidabilità 1,0
“All the cases of spectra that produced 𝐶𝑜 0.5𝑍𝑛 0.5𝐶𝑑 𝑥𝐹𝑒 (2-𝑥)𝑂 cm-1 cm-1), absorption peaks in the fingerprint region (400 -800 which is due to M-O stretching 671 that ensures the presence of ferrites in prepared samples and designates th”
Manimegalai 等 - 2022 - Experimental investigation on ferrofluid propertie DOI: 10.15251/DJNB.2022.172.661 -
Phosphate (PO4) affidabilità 1,0
“ATD-FTIR spectra of the Salisbury's patina exhibit peaks at 2361, 2341 and 671 cm-1 (assigned to phosphates);”
Martin-Gil 等 - 2005 - The orange-brown patina of Salisbury Cathedral (We DOI: 10.1065/espr2005.05.257 -
Metal oxygen affidabilità 1,0
“Also in the fingerprint cm-1 region, it has been observed peaks at around 671 and 507 represent vibration of Ag-O metal oxides [22-24].”
Rupiasih 等 - 2019 - The Current-Voltage Properties of ChAgNP Composit DOI: 10.1088/1757-899X/515/1/012064 -
Alkyl C-H affidabilità 1,0
“cm1 cm1 stretching at 671.43 and 892.51 The peaks at 834.50 and 798.47 indicate C-H”
Agrawal 等 - 2023 - Biotreatment of azo dye containing textile industr DOI: 10.21203/rs.3.rs-1876766/v2 -
Metal oxygen affidabilità 1,0
“Tamilselvi et al., 2013 449cm-1, 511cm-1, 584cm-1, 3.3.1 Combined Effect of Methanol to Oil Molar Ratio observed major peaks at 671cm-1, confirmed and Catalyst Loading which the presence of Mg-O vibrations.”
Ameen 等 - 2022 - Biodiesel Synthesis From Cucumis melo Var. agresti DOI: 10.3389/fenrg.2022.830845 -
affidabilità 1,0
“The absorption band at 671 is assigned to Ni-O-Si in calcined Ni 20/m-SiO 2, Ni 15Cu 5/m-SiO 2, Ni 10Cu 10/m-SiO 2, and Ni 5Cu 15/mcm-1”
Enhanced Cyclopentanone Yield from Furfural Hydrogenation: Promotional Effect of Surface Silanols on Ni-Cu/m-Silica Catalyst DOI: 10.3390/catal13030580 -
Alkene (C=C) affidabilità 1,0
“[BBSQ-FeCl BBSQ-Cu2+ 3+] on ion,34 assigned to while the system Therefore,inordertoexploretheinteractionbetweenBBSQand Commons Downloaded [BBSQ-Cu2+], showed a peak at 671.3481, assigned to and Fe3+, Cu2+, Hg2+, and the metal chelator ethyl”
NIR squaraine dyes for dual colorimetric and fluorescent determination of Fe3+, Cu2+, and Hg2+ ions DOI: 10.1039/d3ra02419a