What absorbs at 604 cm⁻¹ in an FTIR spectrum?
A band near 604 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 604 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Metal oxygen | 4 | 3 | 1,0 |
| Phosphate (PO4) | 2 | 2 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Chlorine | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 0,8 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| chitosan | 604, 1650, 1655 | Alkyl C-H | 1 |
| graphene oxide | 604, 1150, 3400 | Alkyl C-H | 1 |
| silver nanoparticles | 604, 1636, 1631 | Alkyl C-H | 1 |
| dentin | 604, 575, 1740 | Phosphate (PO4), Alkyl C-H | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 604 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Metal oxygen wiarygodność 1,0
“stretching at 604 O-Cr-O bending mode at 419 and Ag-O bands at 561 and 443 The powder X-ray diffraction patterns 2u”
Athawale 和 Desai - 2011 - Silver doped lanthanum chromites by microwave comb DOI: 10.1016/j.ceramint.2011.05.008 -
wiarygodność 1,0
“cm(cid:2)1) at 1153.6 strong sulphate band (1153.6 two shoulders at around 1114 and towards a lower wave cm(cid:2)1 cm(cid:2)1) 1097 number (1097.6 and O-S-O bending band at around 603.7 and (Table 3a) is possibly caused by the P.A.”
Theoretical and experimental study of structures and properties of cement paste The nanostructural aspects of C–S–H DOI: 10.1016/j.jpcs.2011.05.001 -
Phosphate (PO4) wiarygodność 1,0
“Considering the above-described intensity of the sub-band at as well as by meaneeds, this study employed ATR-FTIR to investigate the suringthefullwidthathalfmaximum(FWHM)ofthepeakat 604cm-1 604cm-1, ] effect of these food items on dentin af”
Alebrahim 等 - 2022 - Effect of Exposure to Acidic Food Items on Dentin DOI: 10.1155/2022/8542144 -
Metal oxygen wiarygodność 1,0
“The present peak at 1025 indicates the asymmetric stretching of the C-O-C The peak cm-1 cm-1 821 was due to the bending vibration of C=C and the peak 604 pertained to the stretching vibration of Ni-O, Fe-O, and Co-O in the tetrahedral or oc”
Production of Ni0.5Co0.5Fe2O4/activated carbon@chitosan magnetic nanobiocomposite as a novel adsorbent of methylene blue in aqueous solutions DOI: 10.1038/s41598-023-33470-y -
Acetate wiarygodność 1,0
“cm-1 2351.33 for =C-H stretch, 1739.42 for cm-1 -C-H deformation, 1460.07 for -C-H bending, cm-1 1251.66 and 1025.52 for C-O stretch in -COOH cm-1 group, 604.28 and 657.49 for monosubstituted benzene ring (Fig.”
Haque 等 - 2020 - Degradation of Reactive Blue 19 Dye Using Copper N DOI: 10.15244/pjoes/104663 -
Hydroxyl (O-H) wiarygodność 1,0
“In the FTIR spectra of Fe 3O 4, the peaks at 3413 and cm-1 cm-1 1634 corresponds to the O-H vibration meanwhile the peak at 604 represented Polymers 2022, 14, x FOR PEER REVIEW”
Magnetic Graphene-Based Nanosheets with Pluronic F127-Chitosan Biopolymers Encapsulated -Mangosteen Drugs for Breast Cancer Cells Therapy DOI: 10.3390/polym14153163 -
wiarygodność 1,0
“The bands at 603.71 and 602.71 correspond to the C-Cl (alkyl halides).”
Pirtarighat 等 - 2019 - Green synthesis of silver nanoparticles using the DOI: 10.1007/s40097-018-0291-4 -
wiarygodność 0,9
“Explicit assignment: 'Fe3+-O2- bond at tetrahedral (A-site)'.”
Influence of cobalt substitution on structural, optical, electrical and magnetic properties of nanosized lithium ferrite DOI: 10.1007/s10854-018-9744-2
Masz widmo z tym pasmem?