What absorbs at 3645 cm⁻¹ in an FTIR spectrum?
A band near 3645 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| Hydroxyl (O-H) | 7 | 6 | 1.0 |
| Silicon (Si) | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
これらのアサインの根拠となる文献
-
Hydroxyl (O-H) 信頼度 1.0
“t h o cm-1 bacteriorhodopsin78) The apparent depletion band at ~3645 (first observed in was at r M Tyr-5778”
Dioumaev 等 - 2010 - Low-Temperature FTIR Study of Multiple K Intermedi DOI: 10.1021/jp908698f. -
Hydroxyl (O-H) 信頼度 1.0
“cm-1 In all the paste samples, the peak at 3645 indicates the presence of free OH In all the paste samples, the peak at 3645 cm-1 indicates the presence of free OH groups, which suggests the presence of the portlandite phase.”
Evaluation of Mechanical and Microstructural Properties and Global Warming Potential of Green Concrete with Wheat Straw Ash and Silica Fume DOI: 10.3390/ma15093177 -
Hydroxyl (O-H) 信頼度 1.0
“This resulted in the loss of all B-type carbonate h o cm-1 cm-1 and interestingly, a new hydroxyl peak at 3645 (FTIR spectra) and at 3615 r M”
Carbonate substitution in the mineral component of bone: Discriminating the structural changes, simultaneously imposed by carbonate in A and B sites of apatite DOI: 10.1016/j.jssc.2017.07.025. -
Hydroxyl (O-H) 信頼度 1.0
“LLM confirmed rule peak-group candidate”
Morgan 等 - 2007 - Water structural changes in the L and M photocycle DOI: 10.1021/bi0616596. -
Hydroxyl (O-H) 信頼度 1.0
“LLM confirmed rule peak-group candidate”
Fixed bed adsorption column studies and models for removal of ibuprofen from aqueous solution by strong adsorbent Nano-clay composite DOI: 10.1007/s40201-019-00392-9 -
Hydroxyl (O-H) 信頼度 1.0
“The peak at 3645 was attributed to the hydroxyl groups of the montmorillonite layer [36].”
Adsorption of imidazolium and pyridinium ionic liquids onto montmorillonite: characterization and thermodynamic calculations DOI: 10.1016/j.cej.2012.07.128 -
Silicon (Si) 信頼度 1.0
“Calibration curves tracted by the absorbance of the IR band around 3645 cm due to PE in the pure Si-g-LLDPE) against their concentration gave the calIn a recent study [8] , it was shown that the physical state ibration curve of Fig.”
Physico-chemical analysis of a silane-grafted polyethylene stabilised with an excess of Irganox 1076®. Proposal of a microstructural model DOI: 10.1016/j.polymdegradstab.2020.109453
このバンドを持つスペクトルがありますか?
FTIRスペクトルをアップロードすると、数秒で完全な解釈レポート(文献引用付きピークアサイン、ライブラリマッチ、信頼度評価付き証拠チェーン)を取得できます。
スペクトルを解釈