What absorbs at 3627 cm⁻¹ in an FTIR spectrum?
A band near 3627 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Réponse rapide
A band near 3627 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Attributions possibles de groupes fonctionnels
| Groupe fonctionnel | Faits à l'appui | Sources citées | Confiance maximale |
|---|---|---|---|
| Hydroxyl (O-H) | 4 | 4 | 1,0 |
| Metal hydroxyl | 1 | 1 | 1,0 |
Le classement reflète les preuves bibliographiques accumulées, et non une règle faisant autorité. Confirmez toujours dans le contexte de votre échantillon.
Matériaux possibles
| Matériel | Pics de support | Groupes chevauchants | Sources citées |
|---|---|---|---|
| starch | 3627, 1650, 1540 | Hydroxyl (O-H) | 1 |
| montmorillonite | 3627, 1637, 523 | Hydroxyl (O-H) | 1 |
| glycerol | 3627, 1585, 1630 | Hydroxyl (O-H) | 1 |
Les matériaux sont affichés uniquement lorsque le même ensemble de littérature soutient cette bande et au moins un pic caractéristique supplémentaire.
Logique du spectre
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3627 cm⁻¹ is usually not enough for material identification by itself.
Utilisation réelle
Ce type de requête est courant dans l'identification des polymères, le criblage des plastiques inconnus, le dépannage du contrôle qualité, la vérification des matériaux recyclés et l'examen de l'attribution des pics appuyée par la littérature.
Erreurs courantes
- Traiter une bande isolée comme preuve d'un matériau sans vérifier au moins un ou deux pics de support.
- Ignorer le chevauchement : plusieurs groupes fonctionnels peuvent contribuer près du même nombre d'onde.
- Sauter la validation lorsque des additifs, des mélanges, l'oxydation ou la contamination peuvent déformer le spectre.
Conseil de vérification
Lorsque l'ambiguïté persiste, validez l'hypothèse avec DSC, GC-MS ou TGA, en particulier pour les mélanges, les échantillons dégradés et les polymères chargés.
Bibliographie derrière ces attributions
-
Hydroxyl (O-H) confiance 1,0
“FTIRspectraforstarch/MMTsamplesareshowninFig.2(b),and Increasing the glycerol content further highlights the typical 3627cm-1, the shift of band from the free OH group of pristine anti-plasticization to plasticization threshold, which have”
Glycerol/starch/Na+-montmorillonite nanocomposites: A XRD, FTIR, DSC and 1H NMR study DOI: 10.1016/j.carbpol.2010.10.018 -
Hydroxyl (O-H) confiance 1,0
“OH Stretching Vibrations The FTIR spectra of unheated samples (Na-Mt0, Cu-Mt0 and Li-Mt0) showed an obvicm-1, ous absorption band near 3627 which was the OH group stretching vibration band coordinated with the central atom in the octahedron”
Thermal Migration Behavior of Na+, Cu2+ and Li+in Montmorillonite DOI: 10.3390/min12040477 -
Hydroxyl (O-H) confiance 1,0
“Notably, the observed OH stretching cm(cid:4)1) cm(cid:4)1 formed, and not only as a ''byproduct'' but in similar amounts band (3627 is only 23 lower in wavenumber, similar cm(cid:4)1 as the most stable homochiral dimer.”
Altnoeder 等 - 2013 - Chirality-dependent balance between hydrogen bondi DOI: 10.1039/c3cp50708d -
Hydroxyl (O-H) confiance 1,0
“Instead, within this region of the spectra, a small peak centered around 3627 cm-1 cm-1 cm-1 (outer and inner hydroxyl ion bands), 1028 (Si-O-Si band), and 914 (Al-O-H is present that may be ascribed to Al-OH vibrations in illites [32].”
Investigation of Ancient Wall Painting Fragments Discovered in the Roman Baths from Alburnus Maior by Complementary Non-Destructive Techniques DOI: 10.3390/app112110049
Avez-vous un spectre avec cette bande ?
Téléchargez votre spectre FTIR et obtenez un rapport d'interprétation complet — attributions de pics avec citations bibliographiques, correspondances de bibliothèque et une chaîne de preuves avec évaluation de la confiance — en quelques secondes.