What absorbs at 3626 cm⁻¹ in an FTIR spectrum?
A band near 3626 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Hurtigt svar
A band near 3626 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mulige funktionelle gruppetildelinger
| Funktionel gruppe | Understøttende fakta | Citerede kilder | Højeste tillid |
|---|---|---|---|
| Hydroxyl (O-H) | 6 | 4 | 1,0 |
| Silanol (Si-OH) | 1 | 1 | 1,0 |
| Water (H2O) | 1 | 1 | 1,0 |
| Silicate | 1 | 1 | 0,9 |
Rangering afspejler akkumulerede litteraturbeviser, ikke en enkelt autoritativ regel. Bekræft altid mod din prøvekontekst.
Mulige materialer
| Materiale | Understøttende toppe | Overlappende grupper | Citerede kilder |
|---|---|---|---|
| activated carbon | 3626, 1575, 1210 | Hydroxyl (O-H) | 1 |
| clay | 3626, 1736, 2855 | Hydroxyl (O-H), Water (H2O) | 1 |
| CS | 3626, 1645, 1720 | Hydroxyl (O-H) | 1 |
Materialer vises kun, når den samme litteraturpulje understøtter dette bånd og mindst en yderligere karakteristisk top.
Spektrumlogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3626 cm⁻¹ is usually not enough for material identification by itself.
Anvendelse i virkeligheden
Denne type forespørgsel er almindelig ved polymeridentifikation, screening af ukendt plast, fejlfinding i kvalitetskontrol, verifikation af genanvendt materiale og litteraturunderstøttet gennemgang af peak-tildeling.
Almindelige fejl
- Behandling af et isoleret bånd som bevis på et materiale uden at kontrollere mindst en eller to understøttende toppe.
- Ignorerer overlap: flere funktionelle grupper kan bidrage nær samme bølgetal.
- Spring validering over, når additiver, blandinger, oxidation eller forurening kan forvrænge spektret.
Verifikationsrådgivning
Når tvetydighed fortsat består, valider hypotesen med DSC, GC-MS eller TGA, især for blandinger, nedbrudte prøver og fyldte polymerer.
Litteratur bag disse tildelinger
-
Hydroxyl (O-H) tillid 1,0
“be at 3498 and bonding change of Thr204 occurs without evident structural Secondary alcohols possess their O-H stretches at 3626-”
Kandori 等 - 2010 - Protein-Protein Interaction Changes in an Archaeal DOI: 10.1155/2010/424760 -
Hydroxyl (O-H) tillid 1,0
“Most of the changes in the spectrum of CuMt compared to the spectrum of the NaMt The characteristic absorption band of NaMt at 3626 cm-1 (Figure 2) is assigned to OH cm-1.”
Effect of Copper and Titanium-Exchanged Montmorillonite Nanostructures on the Packaging Performance of Chitosan/Poly-Vinyl-Alcohol-Based Active Packaging Nanocomposite Films DOI: 10.3390/foods10123038 -
Hydroxyl (O-H) tillid 1,0
“LLM confirmed rule peak-group candidate”
Sureshkumar 等 - 2020 - Continuous Phenol Removal Using a Liquid-Solid Cir DOI: 10.3390/en13153839 -
Hydroxyl (O-H) tillid 1,0
“The characteristic peak occurring at a frequency level of 3626 cm-1 indicated the O-H stretching in silanol (Si-OH) groups.”
Insights into Alkali-Acid Leaching of Sericite: Dissolution Behavior and Mechanism DOI: 10.3390/min7100196 -
Silicate tillid 0,9
“absorption bands at 3626 refer to stretching vibration of silicates”
Enhanced Coating Protection of C-Steel Using Polystyrene Clay Nanocomposite Impregnated with Inhibitors DOI: 10.3390/polym15020372
Har du et spektrum med dette bånd?
Upload dit FTIR-spektrum og få en fuld tolkningsrapport — peak-tildelinger med litteraturhenvisninger, biblioteksmatch og en tillidsvurderet beviskæde — på få sekunder.