What absorbs at 3542 cm⁻¹ in an FTIR spectrum?
A band near 3542 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
クイックアンサー
A band near 3542 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| Hydroxyl (O-H) | 5 | 5 | 1.0 |
| Water (H2O) | 1 | 1 | 1.0 |
| N h | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
可能性のある材料
| 素材 | 補助ピーク | 重複グループ | 引用元 |
|---|---|---|---|
| polypropylene | 3542, 1030, 1600 | Hydroxyl (O-H) | 1 |
| Hydroxyapatite | 3542, 1620, 1639 | Hydroxyl (O-H) | 1 |
同じ文献プールがこのバンドと少なくとも1つの追加の特性ピークをサポートする場合にのみ、材料が表示されます。
スペクトルロジック
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3542 cm⁻¹ is usually not enough for material identification by itself.
実使用例
この種のクエリは、ポリマー識別、未知のプラスチックスクリーニング、QCトラブルシューティング、リサイクル材料の検証、および文献に基づいたピーク帰属のレビューで一般的です。
よくある間違い
- 少なくとも1~2つの支持ピークを確認せずに、1つの孤立したバンドを材料の証拠として扱うこと。
- 重複を無視: 複数の官能基が同じ波数付近に寄与することがあります。
- 添加剤、ブレンド、酸化、または汚染がスペクトルを歪める可能性がある場合に検証を省略すること。
検証アドバイス
曖昧さが残る場合は、特にブレンド、劣化サンプル、充填ポリマーについて、DSC、GC-MS、またはTGAで仮説を検証してください。
これらのアサインの根拠となる文献
-
信頼度 1.0
“L¢ cm-1 BR (43), returns to a weaker state in , as judged by both of the intensity of the intense negative band at 3549 CdN N-H L¢ the frequencies of the stretching and bending by half with the remaining band now absorbing at 3542 cm-1 vibr”
Maeda 等 - 1999 - Chromophore-protein-water interactions in the L in DOI: 10.1021/bi9907072 -
Hydroxyl (O-H) 信頼度 1.0
“First, the polymers P1 and P4 showed a stretch peak (around 1736 After the -C=O dehydration reaction, the ester group changed into a hydroxyl group, with the loss of the stretch cm-1 cm-1 -C=O peak and a new -OH stretch peak (3542 for polym”
Chen 等 - 2019 - Simple Route to Synthesize Fully Conjugated Ladder DOI: 10.3390/polym11101619 -
Hydroxyl (O-H) 信頼度 1.0
“LLM confirmed rule peak-group candidate”
Karami 等 - 2020 - Kinetics of Cross-Linking Reaction of Epoxy Resin DOI: 10.3390/polym12051157 -
Hydroxyl (O-H) 信頼度 1.0
“3287 3285 [m 3489 3486 Stretching of water (O-H)] s 3542 3542 (a) (b)”
Effect of preparation conditions on the nanostructure of hydroxyapatite and brushite phases DOI: 10.1007/s13204-015-0509-4 -
Hydroxyl (O-H) 信頼度 1.0
“LLM confirmed rule peak-group candidate”
Song 等 - 2020 - How the hindered amines affect the microstructure DOI: 10.1515/spma-2019-0001 -
Hydroxyl (O-H) 信頼度 0.9
“Explicit assignment in text: 'νOH Depending on the irradiation wavelength'.”
Kosendiak 等 - 2019 - Complexes of Glycolic Acid with Nitrogen Isolated DOI: 10.3390/molecules24183245
このバンドを持つスペクトルがありますか?
FTIRスペクトルをアップロードすると、数秒で完全な解釈レポート(文献引用付きピークアサイン、ライブラリマッチ、信頼度評価付き証拠チェーン)を取得できます。