What absorbs at 3501 cm⁻¹ in an FTIR spectrum?
A band near 3501 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 6 cited sources
Quick answer
A band near 3501 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Hydroxyl (O-H) | 4 | 4 | 1,0 |
| Water (H2O) | 2 | 2 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Carbon dioxide | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Possible materials
| Material | Unterstützende Peaks | Overlapping groups | Zitierte Quellen |
|---|---|---|---|
| PLA | 3501, 1650, 1073 | Hydroxyl (O-H) | 1 |
| PLLA | 3501, 1182, 921 | Water (H2O) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3501 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatur hinter diesen Zuweisungen
-
Alkyl C-H Vertrauen 1,0
“CH stretching is rep3501 resentedbythreepeaksat2996,2945,and2879cm(cid:3)1 withvarying C@O intensity [29].”
Time series Fourier transform infrared spectroscopy for characterization of water vapor sorption in hydrophilic and hydrophobic polymeric films DOI: 10.1016/j.saa.2020.119371 -
Water (H2O) Vertrauen 1,0
“stretching (5) Si-O asymmetric 1153 1182 1189 1185 1196 stretching (6) N-H(cid:5)(cid:5)(cid:5)N stretching 3344 - - - - (7) N-H stretching 3399 3389 3386 - - (8) H-O-H stretching 3501 - - - -”
Ay 和 Aydinli - 2004 - Comparative investigation of hydrogen bonding in s DOI: 10.1016/j.optmat.2003.12.004 -
Hydroxyl (O-H) Vertrauen 1,0
“Other peaks in printed PLA include: the CH3 stretching vibrations at 2829 and 2932 cm-1 and OH stretching vibrations at 3501 and 3667 cm-1 due to the hygroscopic nature of PLA (although these features can also be attributed to the C=O overt”
Impact of the Fused Deposition (FDM) Printing Process on Polylactic Acid (PLA) Chemistry and Structure DOI: 10.3390/app7060579 -
Hydroxyl (O-H) Vertrauen 1,0
“The band at 3501 (-) in the Q A-/Q spectra, A I 218O, H which did not show isotope shift by H probably comes from O-H or N-H stretch of - apoprotein.”
Iwata 等 - 2009 - Identification of FTIR Bands Due to Internal Water DOI: 10.1021/bi801990s. -
Hydroxyl (O-H) Vertrauen 0,9
“Strongest peak assigned to O-H group.”
Molano-Mendoza 等 - 2018 - Synthesis of Mg-Al layered double hydroxides by el DOI: 10.1016/j.mex.2018.07.019 -
Vertrauen 0,9
“Same sentence as above.”
Simu 等 - 2022 - Thermal Degradation Process of Ethinylestradiol-Ki DOI: 10.3390/pr10081518
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.