What absorbs at 3479 cm⁻¹ in an FTIR spectrum?
A band near 3479 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Răspuns rapid
A band near 3479 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Atribuiri posibile ale grupelor funcționale
| Grup funcțional | Fapte suport | Surse citate | Încredere maximă |
|---|---|---|---|
| Hydroxyl (O-H) | 3 | 3 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
Clasamentul reflectă dovezile acumulate din literatură, nu o singură regulă autoritară. Confirmați întotdeauna în contextul mostrei dvs.
Logica spectrului
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3479 cm⁻¹ is usually not enough for material identification by itself.
Utilizare în condiții reale
Acest tip de interogare este comun în identificarea polimerilor, screeningul materialelor plastice necunoscute, depanarea QC, verificarea materialelor reciclate și revizuirea atribuirii vârfurilor bazată pe literatură.
Greșeli comune
- Tratarea unei benzi izolate ca dovadă a unui material fără a verifica cel puțin unul sau două vârfuri de susținere.
- Ignorând suprapunerea: mai multe grupuri funcționale pot contribui în apropierea aceluiași număr de undă.
- Omiterea validării atunci când aditivii, amestecurile, oxidarea sau contaminarea pot distorsiona spectrul.
Sfat de verificare
Când ambiguitatea rămâne, validați ipoteza prin DSC, GC-MS sau TGA, în special pentru amestecuri, probe degradate și polimeri umpluți.
Literatura din spatele acestor atribuiri
-
Hydroxyl (O-H) încredere 1,0
“For pure MC, absorption peaks were observed at 3479 cm-1, cm-1, 2907 and 1057 which correspond to O-H stretching, C-H (in CH 2) stretching, and C-O-C stretching, respectively [7,21,46].”
Innovative Methylcellulose-Polyvinyl Pyrrolidone-Based Solid Polymer Electrolytes Impregnated with Potassium Salt: Ion Conduction and Thermal Properties DOI: 10.3390/polym14153055 -
încredere 1,0
“While cm-1 cm-1 shows absorption bands at 3479 studying Figure 2A, N-H vibrations were observed at and 1720 corcm-1 cm-1 3324 responding to the hydroxyl and carbonyl groups, respecand 1598 for NF-NDs/PAP/PANi/PTh.”
Ashraf 等 - 2014 - Preparation and properties of multilayered polymer DOI: 10.1515/polyeng-2013-0297 -
Hydroxyl (O-H) încredere 1,0
“The infrared spectrum of the DEPH show characteristic bands 2 cm-1 at 3479 attributed to the phenolic hydroxyl group, while the characteristic absorptions at 3076 and cm-1 2981, 1605, 1543 and 1470, 1288 and 1241 can be assigned to Ѵ (CH3/C”
Synthesis, Characterization and Biological Studies of Metal(II) Complexes of (3E)-3-[(2-{(E)-[1-(2,4-Dihydroxyphenyl)ethylidene]amino}ethyl)imino]-1-phenylbutan-1-one Schiff Base DOI: 10.3390/molecules20069788 -
Amide încredere 1,0
“Therefore, it is D 3479-cm-1 band in the wild type peptide backbone originate from ppR [13].”
Kandori 等 - 2010 - Protein-Protein Interaction Changes in an Archaeal DOI: 10.1155/2010/424760