What absorbs at 3479 cm⁻¹ in an FTIR spectrum?
A band near 3479 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Resposta rápida
A band near 3479 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possíveis atribuições de grupos funcionais
| Grupo funcional | Fatos de suporte | Fontes citadas | Maior confiança |
|---|---|---|---|
| Hydroxyl (O-H) | 3 | 3 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
A classificação reflete a evidência acumulada da literatura, não uma única regra autoritária. Sempre confirme com o contexto da sua amostra.
Lógica do espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3479 cm⁻¹ is usually not enough for material identification by itself.
Uso no mundo real
Este tipo de consulta é comum em identificação de polímeros, triagem de plásticos desconhecidos, solução de problemas de CQ, verificação de materiais reciclados e revisão de atribuição de picos apoiada pela literatura.
Erros comuns
- Tratar uma banda isolada como prova de um material sem verificar pelo menos um ou dois picos de suporte.
- Ignorando sobreposição: vários grupos funcionais podem contribuir próximo ao mesmo número de onda.
- Ignorar a validação quando aditivos, misturas, oxidação ou contaminação podem distorcer o espectro.
Conselho de verificação
Quando a ambiguidade persistir, valide a hipótese com DSC, GC-MS ou TGA, especialmente para misturas, amostras degradadas e polímeros carregados.
Literatura por trás destas atribuições
-
Hydroxyl (O-H) confiança 1,0
“For pure MC, absorption peaks were observed at 3479 cm-1, cm-1, 2907 and 1057 which correspond to O-H stretching, C-H (in CH 2) stretching, and C-O-C stretching, respectively [7,21,46].”
Innovative Methylcellulose-Polyvinyl Pyrrolidone-Based Solid Polymer Electrolytes Impregnated with Potassium Salt: Ion Conduction and Thermal Properties DOI: 10.3390/polym14153055 -
confiança 1,0
“While cm-1 cm-1 shows absorption bands at 3479 studying Figure 2A, N-H vibrations were observed at and 1720 corcm-1 cm-1 3324 responding to the hydroxyl and carbonyl groups, respecand 1598 for NF-NDs/PAP/PANi/PTh.”
Ashraf 等 - 2014 - Preparation and properties of multilayered polymer DOI: 10.1515/polyeng-2013-0297 -
Hydroxyl (O-H) confiança 1,0
“The infrared spectrum of the DEPH show characteristic bands 2 cm-1 at 3479 attributed to the phenolic hydroxyl group, while the characteristic absorptions at 3076 and cm-1 2981, 1605, 1543 and 1470, 1288 and 1241 can be assigned to Ѵ (CH3/C”
Synthesis, Characterization and Biological Studies of Metal(II) Complexes of (3E)-3-[(2-{(E)-[1-(2,4-Dihydroxyphenyl)ethylidene]amino}ethyl)imino]-1-phenylbutan-1-one Schiff Base DOI: 10.3390/molecules20069788 -
Amide confiança 1,0
“Therefore, it is D 3479-cm-1 band in the wild type peptide backbone originate from ppR [13].”
Kandori 等 - 2010 - Protein-Protein Interaction Changes in an Archaeal DOI: 10.1155/2010/424760
Tem um espectro com esta banda?
Carregue seu espectro FTIR e obtenha um relatório de interpretação completo — atribuições de picos com citações da literatura, correspondências de biblioteca e uma cadeia de evidências com nível de confiança — em segundos.