What absorbs at 3083 cm⁻¹ in an FTIR spectrum?
A band near 3083 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Quick answer
A band near 3083 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能性のある官能基アサイン
| 官能基 | 裏付け事実 | 引用元 | 最高信頼度 |
|---|---|---|---|
| Alkyl C-H | 3 | 3 | 1.0 |
| Aromatic ring | 2 | 2 | 1.0 |
| Water (H2O) | 1 | 1 | 1.0 |
| Hydroxyl (O-H) | 1 | 1 | 1.0 |
| N h | 1 | 1 | 1.0 |
ランキングは蓄積された文献証拠を反映しており、単一の権威あるルールではありません。常にサンプルのコンテキストと照合して確認してください。
Possible materials
| 素材 | 補助ピーク | Overlapping groups | 引用元 |
|---|---|---|---|
| polysaccharide | 3083, 1637, 1320 | Hydroxyl (O-H), Alkyl C-H | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3083 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
これらのアサインの根拠となる文献
-
Aromatic ring 信頼度 1.0
“The 2 cm.-1 cm-1 aromatic C-H stretching is visible at 3083 N-H bending is seen at 1620 while carbonyl cm-1.”
Synthesis of Aloevera/Acrylonitrile based Nanoparticles for targeted drug delivery of 5-Aminosalicylic acid DOI: 10.1016/j.ijbiomac.2017.08.085 -
Alkyl C-H 信頼度 1.0
“They (C-H stretching reported that the frequencies of allicin in FTIR spectra were 3083 cm-1 2), 2978 cm-1 (C-H stretching symmetric of =CH 2),1634 cm-1 (a medium asymmetric of =CH”
Tasci 等 - 2016 - Determination of alliin and allicin in the plant o DOI: 10.17660/ActaHortic.2016.1143.19 -
Aromatic ring 信頼度 1.0
“The aromatic C-H stretching peaks at 3083, 3063 and 3030 are evident together with the non-aromatic C-H stretching bands at 2959 (-CH 3), 2924 (-CH 2) and 2870 (-CH 3) cm-1.”
Germinario 等 - 2016 - Chemical characterisation of spray paints by a mul DOI: 10.1016/j.microc.2015.04.016 -
Hydroxyl (O-H) 信頼度 1.0
“A broad band centered around 3083 cm-1 in Mt was due to the H-O-H stretching vibration surface adsorbed water of Mt and the band at 2510 cm-1 was due to surface and/or interlayer water arising because of the combination of two vibrational f”
Fabrication of Colored Polymeric Membrane Using Clay-Based Nano Pigments of Safranin O (SO) Dye DOI: 10.3390/membranes13070619
このバンドを持つスペクトルがありますか?
FTIRスペクトルをアップロードすると、数秒で完全な解釈レポート(文献引用付きピークアサイン、ライブラリマッチ、信頼度評価付き証拠チェーン)を取得できます。