What absorbs at 2907 cm⁻¹ in an FTIR spectrum?
A band near 2907 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Câu trả lời nhanh
A band near 2907 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Gán nhóm chức có thể
| Nhóm chức | Sự kiện hỗ trợ | Nguồn tham khảo | Độ tin cậy cao nhất |
|---|---|---|---|
| Alkyl C-H | 8 | 8 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
Xếp hạng phản ánh bằng chứng tài liệu tích lũy, không phải một quy tắc duy nhất có thẩm quyền. Luôn xác nhận với ngữ cảnh mẫu của bạn.
Vật liệu có thể
| Vật liệu | Các đỉnh hỗ trợ | Các nhóm chồng chéo | Nguồn tham khảo |
|---|---|---|---|
| PVA | 2907, 1660, 2930 | Alkyl C-H, Methacrylate, Methoxy (OCH3) | 1 |
| Chitosan | 2907, 1650, 1655 | Alkyl C-H, Methacrylate, Methoxy (OCH3) | 1 |
| Fe3O4 | 2907, 2358, 1673 | Alkyl C-H, Methacrylate | 1 |
| proteins | 2907, 1735, 1270 | Methacrylate, Alkyl C-H, Methoxy (OCH3) | 1 |
Vật liệu chỉ được hiển thị khi cùng một nhóm tài liệu hỗ trợ dải này và ít nhất một đỉnh đặc trưng bổ sung.
Logic phổ
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2907 cm⁻¹ is usually not enough for material identification by itself.
Sử dụng thực tế
Loại truy vấn này phổ biến trong việc xác định polyme, sàng lọc nhựa chưa xác định, xử lý sự cố QC, xác minh vật liệu tái chế và đánh giá gán đỉnh dựa trên tài liệu.
Các lỗi thường gặp
- Xem xét một dải đơn lẻ như bằng chứng của một vật liệu mà không kiểm tra ít nhất một hoặc hai đỉnh hỗ trợ.
- Bỏ qua chồng lấn: nhiều nhóm chức có thể đóng góp gần cùng một số sóng.
- Bỏ qua xác nhận khi các chất phụ gia, hỗn hợp, quá trình oxy hóa hoặc nhiễm bẩn có thể làm méo phổ.
Lời khuyên xác minh
Khi vẫn còn sự mơ hồ, hãy xác thực giả thuyết bằng DSC, GC-MS hoặc TGA, đặc biệt đối với hỗn hợp, mẫu suy thoái và polyme độn.
Tài liệu tham khảo đằng sau các gán này
-
Acetate độ tin cậy 1,0
“on 1412 CH2, CH3 bending Acid phosphatase [31, 35] 16 Island 1447 CH2, CH3 bending Tryptophane [31] It is worth mention that the peaks at 2907 and 2968 17 1667 Amide I Protein [27] cm-1 haven't been characterized and discussed in”
Zou 等 - 2016 - Whole blood and semen identification using mid-inf DOI: 10.1039/C5AY03337C. -
Alkyl C-H độ tin cậy 1,0
“For AD-rhEPO, the cm-1 alone.Theseresultswereinaccordancewiththeresultsreband at 2907.3 represents the -C-H groups of AD, and cm-1”
Application of SPRA Technology for Delivery of Erythropoietin: Stability Evaluation of Conjugated Erythropoietin with Adamantane and in SPRA Inclusion Complex DOI: 10.5812/ijpr-134282. -
Alkyl C-H độ tin cậy 1,0
“The mecm(cid:2)1 cm(cid:2)1 dium band at 2944 with shoulder at 2907 can be assigned to the stretchcm(cid:2)1 ing vibrations of CH 2.”
Synthesis, crystal structure, and characterization of cyclohexylammonium tetraisothiocyanatocobaltate(II): A single-source precursor for cobalt sulfide and oxide nanostructures DOI: 10.1016/j.heliyon.2019. -
Alkyl C-H độ tin cậy 1,0
“Adcm-1 ditionally, there are two bands at 2907 and 1402 which attributed to C-H stretching vibration and in-plane respectively31.”
Fabrication of attapulgite/magnetic aminated chitosan composite as efficient and reusable adsorbent for Cr (VI) ions DOI: 10.1038/s41598-021-96145-6 -
Alkyl C-H độ tin cậy 1,0
“N-H the broadband at 3244 shifting of this band was accentuated as the LiClO is attributed to the 4 stretching.79 cm-1 The absorbance band at 2907 is associated concentration increased, which seems to suggest an interaction OHLi+ C-H with s”
Gurumendi 等 - 2023 - Enhanced Chitosan Photoluminescence by Incorporati DOI: 10.1021/acsomega.2c08072 -
Alkyl C-H độ tin cậy 1,0
“2963, 2907 cm-1 cm-1 and 2873 were the stretching vibration absorption peaks of saturated C-H, 1730 was the stretching”
Terpolymer resin containing bioinspired borneol and controlled release of camphor: Synthesis and antifouling coating application DOI: 10.1038/s41598-020-67073-8 -
Alkyl C-H độ tin cậy 1,0
“The peaks that appeared at 2937 cm-1 and 2907 cm-1 were due to the symmetric and asymmetric stretching vibration peaks of methylene [46].”
Preparation of a Cation Exchange Membrane by a Sol-Gel Method-Based Polyvinyl Alcohol to Improve Alkali Recovery via Diffusion Dialysis in the Textile Industry DOI: 10.3390/separations10070370 -
Alkyl C-H độ tin cậy 0,9
“Stretching vibrations of C-H.”
Fungal Biodeterioration of a Historical Manuscript Dating Back to the 14th Century: An Insight into Various Fungal Strains and Their Enzymatic Activities DOI: 10.3390/life12111821
Có phổ với dải này không?
Tải lên phổ FTIR của bạn và nhận báo cáo diễn giải đầy đủ — gán đỉnh với tài liệu tham khảo, kết quả so khớp thư viện và chuỗi bằng chứng xếp hạng độ tin cậy — trong vài giây.