What absorbs at 2907 cm⁻¹ in an FTIR spectrum?
A band near 2907 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Tez cavab
A band near 2907 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mümkün funksional qrup təyinatları
| Funksional qrup | Dəstəkləyici faktlar | İstinad edilən mənbələr | Ən yüksək etibarlılıq |
|---|---|---|---|
| Alkyl C-H | 8 | 8 | 1,0 |
| Methyl | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
Sıralama toplanmış ədəbiyyat sübutlarını əks etdirir, tək səlahiyyətli qayda deyil. Həmişə nümunə kontekstinizə qarşı təsdiqləyin.
Mümkün materiallar
| Material | Dəstəkləyən zirvələr | Üst-üstə düşən qruplar | İstinad edilən mənbələr |
|---|---|---|---|
| PVA | 2907, 1660, 2930 | Alkyl C-H, Methacrylate, Methoxy (OCH3) | 1 |
| Chitosan | 2907, 1650, 1655 | Alkyl C-H, Methacrylate, Methoxy (OCH3) | 1 |
| Fe3O4 | 2907, 2358, 1673 | Alkyl C-H, Methacrylate | 1 |
| proteins | 2907, 1735, 1270 | Methacrylate, Alkyl C-H, Methoxy (OCH3) | 1 |
Materiallar yalnız eyni ədəbiyyat hovuzu bu bandı və ən azı bir əlavə xarakterik piki dəstəklədikdə göstərilir.
Spektr məntiqi
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2907 cm⁻¹ is usually not enough for material identification by itself.
Real dünya istifadəsi
Bu tip sorğu polimer identifikasiyası, naməlum plastik skrininqi, keyfiyyətə nəzarət problemlərinin həlli, təkrar emal edilmiş materialın yoxlanılması və ədəbiyyatla dəstəklənən pik təyinatının icmalında yaygındır.
Ümumi səhvlər
- Ən azı bir və ya iki dəstəkləyici zirvəni yoxlamadan bir təcrid olunmuş zolağı materialın sübutu kimi qəbul etmək.
- Üst-üstə düşməyə məhəl qoyulmur: eyni dalğa nömrəsi yaxınlığında bir neçə funksional qrup təsir göstərə bilər.
- Aşqarlar, qarışıqlar, oksidləşmə və ya çirklənmə spektri təhrif edə bildikdə yoxlamanı atlamaq.
Doğrulama məsləhəti
Qeyri-müəyyənlik qaldıqda, fərziyyəni DSC, GC-MS və ya TGA ilə təsdiqləyin, xüsusən qarışıqlar, deqradasiyaya uğramış nümunələr və doldurulmuş polimerlər üçün.
Bu təyinatların arxasındakı ədəbiyyat
-
Acetate etibarlılıq 1,0
“on 1412 CH2, CH3 bending Acid phosphatase [31, 35] 16 Island 1447 CH2, CH3 bending Tryptophane [31] It is worth mention that the peaks at 2907 and 2968 17 1667 Amide I Protein [27] cm-1 haven't been characterized and discussed in”
Zou 等 - 2016 - Whole blood and semen identification using mid-inf DOI: 10.1039/C5AY03337C. -
Alkyl C-H etibarlılıq 1,0
“For AD-rhEPO, the cm-1 alone.Theseresultswereinaccordancewiththeresultsreband at 2907.3 represents the -C-H groups of AD, and cm-1”
Application of SPRA Technology for Delivery of Erythropoietin: Stability Evaluation of Conjugated Erythropoietin with Adamantane and in SPRA Inclusion Complex DOI: 10.5812/ijpr-134282. -
Alkyl C-H etibarlılıq 1,0
“The mecm(cid:2)1 cm(cid:2)1 dium band at 2944 with shoulder at 2907 can be assigned to the stretchcm(cid:2)1 ing vibrations of CH 2.”
Synthesis, crystal structure, and characterization of cyclohexylammonium tetraisothiocyanatocobaltate(II): A single-source precursor for cobalt sulfide and oxide nanostructures DOI: 10.1016/j.heliyon.2019. -
Alkyl C-H etibarlılıq 1,0
“Adcm-1 ditionally, there are two bands at 2907 and 1402 which attributed to C-H stretching vibration and in-plane respectively31.”
Fabrication of attapulgite/magnetic aminated chitosan composite as efficient and reusable adsorbent for Cr (VI) ions DOI: 10.1038/s41598-021-96145-6 -
Alkyl C-H etibarlılıq 1,0
“N-H the broadband at 3244 shifting of this band was accentuated as the LiClO is attributed to the 4 stretching.79 cm-1 The absorbance band at 2907 is associated concentration increased, which seems to suggest an interaction OHLi+ C-H with s”
Gurumendi 等 - 2023 - Enhanced Chitosan Photoluminescence by Incorporati DOI: 10.1021/acsomega.2c08072 -
Alkyl C-H etibarlılıq 1,0
“2963, 2907 cm-1 cm-1 and 2873 were the stretching vibration absorption peaks of saturated C-H, 1730 was the stretching”
Terpolymer resin containing bioinspired borneol and controlled release of camphor: Synthesis and antifouling coating application DOI: 10.1038/s41598-020-67073-8 -
Alkyl C-H etibarlılıq 1,0
“The peaks that appeared at 2937 cm-1 and 2907 cm-1 were due to the symmetric and asymmetric stretching vibration peaks of methylene [46].”
Preparation of a Cation Exchange Membrane by a Sol-Gel Method-Based Polyvinyl Alcohol to Improve Alkali Recovery via Diffusion Dialysis in the Textile Industry DOI: 10.3390/separations10070370 -
Alkyl C-H etibarlılıq 0,9
“Stretching vibrations of C-H.”
Fungal Biodeterioration of a Historical Manuscript Dating Back to the 14th Century: An Insight into Various Fungal Strains and Their Enzymatic Activities DOI: 10.3390/life12111821
Bu zolaqlı spektriniz varmı?
FTIR spektrinizi yükləyin və saniyələr ərzində tam interpretasiya hesabatı əldə edin — ədəbiyyat istinadları ilə pik təyinatları, kitabxana uyğunluqları və etibarlılıq dərəcəsi olan sübut zənciri.