What absorbs at 2906 cm⁻¹ in an FTIR spectrum?
A band near 2906 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Alkyl C-H | 8 | 8 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Letteratura dietro queste assegnazioni
-
Alkyl C-H affidabilità 1,0
“0.626±0.007 0.623±0.006 0.60 *** CH3 asymmetric stretching 2944.54±0.17 2944.59±0.29 0.81 0.719±0.030 0.074±0.036 CH2 asymmetric stretching 2905.65±0.58 2905.45±0.17 0.60 0.630±0.021 0.642±0.028 0.58 CH3 symmetric stretching”
Differentiation in MALDI-TOF MS and FTIR spectra between two pathovars of Xanthomonas oryzae DOI: 10.1016/j.saa.2014.06.056 -
Hydroxyl (O-H) affidabilità 1,0
“In a comparison, the band peaked at 2906 cm-1 can be attributed to presence of OH groups that could be confirmed by the appearance of broad band with a maximum at 3351cm-1 cm-1 C-H stretching in dextran [32,33], since such band was not obse”
Development of Polymer Blend Electrolyte Membranes Based on Chitosan: Dextran with High Ion Transport Properties for EDLC Application DOI: 10.3390/ijms20133369 -
Alkyl C-H affidabilità 1,0
“This is convincing evidence of an increased amorphous region within at 3351cm⁻1 as shown in Figure 4c [51,52].Figure 4calso exhibits a band at 2906 cm⁻1that is related to C-H stretching [51-53].”
Structural, Impedance and Electrochemical Characteristics of Electrical Double Layer Capacitor Devices Based on Chitosan: Dextran Biopolymer Blend Electrolytes DOI: 10.3390/polym12061411 -
Alkyl C-H affidabilità 1,0
“cm-1 as gas phase methane at 3015 In addition, peaks are present at 2906 and a cm-1 sym shoulder at 2885 which are attributed to a methine (CH) stretching mode and the”
Mcnab 等 - 2017 - Quantification and qualification by in-situ FTIR o DOI: 10.1016/S0926-860X(99)00160-X. -
Alkyl C-H affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Preparation and Optimization of Water-Soluble Cationic Sago Starch with a High Degree of Substitution Using Response Surface Methodology DOI: 10.3390/polym12112614 -
Alkyl C-H affidabilità 1,0
“2937.98 C-H stretching 2906.38 C-H stretching 2872.47 =”
Development of Flexible Plasticized Ion Conducting Polymer Blend Electrolytes Based on Polyvinyl Alcohol (PVA): Chitosan (CS) with High Ion Transport Parameters Close to Gel Based Electrolytes DOI: 10.3390/gels -
Alkyl C-H affidabilità 1,0
“The peak at 2906 corresponds with the asymmetric and symmetric cm-1 stretching of -CH groups [32,36].”
Design of Asymmetric Nanofibers-Membranes Based on Polyvinyl Alcohol and Wool-Keratin for Wound Healing Applications DOI: 10.3390/jfb12040076 -
Alkyl C-H affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Sandu 等 - 2023 - Authentication of a Stradivarius Petite Violin T DOI: 10.3390/app