What absorbs at 2869 cm⁻¹ in an FTIR spectrum?
A band near 2869 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 2869 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Alkyl C-H | 12 | 12 | 1,0 |
| Aldehyde (CHO) | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Possible materials
| Material | Unterstützende Peaks | Overlapping groups | Zitierte Quellen |
|---|---|---|---|
| polyurethanes | 2869, 1740, 1728 | Alkyl C-H | 1 |
| HCl | 2869, 1708, 1032 | Carbohydrate | 1 |
| graphite | 2869, 1640, 1326 | Alkyl C-H | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2869 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literatur hinter diesen Zuweisungen
-
Alkyl C-H Vertrauen 1,0
“More invasive and time consuming vibration of the lipid hydrocarbon tail was observed at 2921 and 2854 cm-1 (CH 2), as well methods are used to identify the exact chemical composition, such as gas chromatography as at 2960 and 2869 cm-1 (CH”
Assessing the Biofilm Formation Capacity of the Wine Spoilage Yeast Brettanomyces bruxellensis through FTIR Spectroscopy DOI: 10.3390/microorganisms9030587 -
Alkyl C-H Vertrauen 1,0
“asym ν methylene (CH 2), C-H asymmetric stretching 2927 asym ν methyl (CH 3), C-H symmetric stretching 2869 sym ν vinyl (C=C), stretching (origin CH=CH) 1629”
Filip 等 - 2013 - Investigation of thermal and catalytic degradation DOI: 10.2478/s11532-013-0202-y -
Alkyl C-H Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
Physicochemical Properties of Membrane Adsorber from Palm Empty Fruit Bunch (PEFB) by Acid Activation DOI: 10.3390/membranes11120917 -
Alkyl C-H Vertrauen 1,0
“(C-H PEG, such as methylene stretch near 2869, 2826 and thesp2 This E phonon of carbonatoms.”
Huang 等 - 2019 - Effects of poly(ethylene glycol)-grafted graphene DOI: 10.1039/c9ra01060b -
Alkyl C-H Vertrauen 1,0
“CH symmetric stretching”
Kavanaugh 等 - 2016 - Human mesenchymal stem cell behavior on segmented DOI: 10.1007/s10856-015-5654-5. -
Alkyl C-H Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
Mir 等 - 2022 - Chemical composition and insecticidal activity of DOI: 10.47665/tb.39.2.005 -
Alkyl C-H Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
Effects of Various Types of Expandable Graphite and Blackcurrant Pomace on the Properties of Viscoelastic Polyurethane Foams DOI: 10.3390/ma14071801 -
Alkyl C-H Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
Design and Synthesis of Amphiphilic Graft Polyphosphazene Micelles for Docetaxel Delivery DOI: 10.3390/pharmaceutics15051564
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.