What absorbs at 2866 cm⁻¹ in an FTIR spectrum?
A band near 2866 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 2866 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Alkyl C-H | 11 | 11 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
| Methoxy (OCH3) | 1 | 1 | 1,0 |
| Methacrylate | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 1,0 |
| Acetate | 1 | 1 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| PCL | 2866, 1751, 1724 | Alkyl C-H, Hydroxyl (O-H) | 2 |
| cellulose | 2866, 1735, 1650 | Alkyl C-H, Hydroxyl (O-H) | 1 |
| hemicellulose | 2866, 1730, 897 | Alkyl C-H, Hydroxyl (O-H) | 1 |
| polyurethane | 2866, 2270, 1700 | Alkyl C-H | 1 |
| graphene | 2866, 1720, 2097 | Hydroxyl (O-H) | 1 |
| GO | 2866, 1720, 1182 | Hydroxyl (O-H), Alkyl C-H | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2866 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
Alkyl C-H wiarygodność 1,0
“cm-1 peaks at 2865.67 and 2918.4 corresponding to stretching vibration of C H bonds in the high frequency area together cm-1 with a sharp peak at 1465.95 corresponding to the bending vibration of C H groups of water molecules adsorbed cm-1”
Production of graphene powder by electrochemical exfoliation of graphite electrodes immersed in aqueous solution DOI: 10.1016/j.ijleo.2016.04.101 -
wiarygodność 1,0
“Explicit assignment in text”
Lu 和 Mi - 2005 - Characterization of the interfacial interaction be DOI: 10.1021/ma0486896 -
Alkyl C-H wiarygodność 1,0
“In addition, the presence of the C-H stretching at 2931 cm-1 and 2866 cm-1, C=O urethane linkage [33].”
Self-Healable Supramolecular Vanadium Pentoxide Reinforced Polydimethylsiloxane-Graft- Polyurethane Composites DOI: 10.3390/polym11010041 -
Acetate wiarygodność 1,0
“cm-1 cm-1, C=O (symmetric), stretching at 1721 at 2866 cm-1, C-O-C stretching C-C and C-O stretching at 1721”
Preparation of electrospun polycaprolactone nanofiber mats loaded with microalgal extracts DOI: 10.1002/elsc.201900009 -
Alkyl C-H wiarygodność 1,0
“cm-1 C-H asymmetric stretching), 2929 (methylene C-H peak near 122.1 (cid:3)C does not vary with the mass ratio of cm-1 asymmetric stretching), 2866 (methyl and methylene LOV and indicates the temperature of the eutectic reaction: cm-1 C-H”
Gorniak 等 - 2016 - Thermal, spectroscopic and dissolution studies of DOI: 10.1007/s10973-016-5279-z -
Alkyl C-H wiarygodność 1,0
“cm-1 cm-1 cm-1 bands at 2945 (asym CH stretch), 2866 (sym CH stretch), 1730 (ester C = O 2 2 cm-1 stretch), and 1060-1150 (asym C-O-C stretch) [36].”
Adapalene-loaded poly(#_#x03B5;-caprolactone) microparticles: Physicochemical characterization and in vitro penetration by photoacoustic spectroscopy DOI: 10.1371/journal. -
Alkyl C-H wiarygodność 1,0
“region arising from C-H stretching of aromatic 2866 and cm-1 compound.”
Antibacterial Potential of Bacterial Cellulose Impregnated with Green Synthesized Silver Nanoparticle Against S. aureus and P. aeruginosa DOI: 10.1007/s00284-023-03182-7 -
Alkyl C-H wiarygodność 1,0
“The positive band at cm-1 cm-1 2993-2995 and the negative band at 2866 (C-H stretching region) demonstrated the difference between normal colon tissues and polyps in the contributions of various”
Ex Vivo Vibration Spectroscopic Analysis of Colorectal Polyps for the Early Diagnosis of Colorectal Carcinoma DOI: 10.3390/diagnostics11112048
Masz widmo z tym pasmem?
Prześlij swoje widmo FTIR i uzyskaj pełny raport interpretacji — przypisania pików z cytowaniami literaturowymi, dopasowania biblioteczne oraz łańcuch dowodów z oceną wiarygodności — w kilka sekund.