What absorbs at 2560 cm⁻¹ in an FTIR spectrum?
A band near 2560 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Quick answer
A band near 2560 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能的官能团归属
| 官能团 | 支持性事实 | 引用来源 | 最高置信度 |
|---|---|---|---|
| Thiol | 4 | 3 | 1.0 |
| Hydroxyl (O-H) | 1 | 0 | 1.0 |
排名反映了累积的文献证据,而非单一的权威规则。请始终对照您的样品背景进行确认。
Possible materials
| 材料 | 支持峰 | Overlapping groups | 引用来源 |
|---|---|---|---|
| keratin | 2560, 1635, 1717 | Hydroxyl (O-H) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2560 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
这些分配背后的文献
-
Thiol 置信度 1.0
“4B, the double mutant C78/122S 2560cm(cid:3)1, did not show an apparent absorptivity around indicatb1(1-194) sGC was S-nitrosated by GSNO ingthatthethiolsignalfromC174wasveryweak.Thepeakaround 2560cm(cid:3)1 is mainly contributed by the S-H”
Liu 等 - 2015 - The process of S-nitrosation in sGC beta 1(1-194) DOI: 10.1016/j.molstruc.2015.02.056 -
Thiol 置信度 0.9
“Text: 'stretching S-H bonds vibration was observed at ... 2560 cm-1'.”
Ciurko 等 - 2019 - Enzymatic bioconversion of feather waste with kera DOI: 10.2478/pjct-2019-0030 -
置信度 0.8
“Shifted peak upon ligand binding, still attributed to sulfhydryl groups.”
Guarrera 等 - 1999 - Ligand-linked changes at the subunit interfaces in DOI: 10.1021/bi990942k -
Thiol 置信度 0.7
“Shoulder of shifted S-H stretch”
Chavan 等 - 2013 - Fundamental Aspects of H2S Adsorption on CPO-27-Ni DOI: 10.1021/jp402440u
是否有此波段的光谱?
上传您的FTIR光谱,几秒钟内即可获得完整的解读报告——包含带文献引用的峰分配、库匹配和带有置信度评级的证据链。