What absorbs at 2112 cm⁻¹ in an FTIR spectrum?
A band near 2112 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Resposta rápida
A band near 2112 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possíveis atribuições de grupos funcionais
| Grupo funcional | Fatos de suporte | Fontes citadas | Maior confiança |
|---|---|---|---|
| Adsorbed carbon monoxide | 2 | 1 | 1,0 |
| Azide | 1 | 1 | 1,0 |
| Carbon dioxide | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 0 | 1,0 |
| C#c | 1 | 0 | 1,0 |
A classificação reflete a evidência acumulada da literatura, não uma única regra autoritária. Sempre confirme com o contexto da sua amostra.
Lógica do espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2112 cm⁻¹ is usually not enough for material identification by itself.
Uso no mundo real
Este tipo de consulta é comum em identificação de polímeros, triagem de plásticos desconhecidos, solução de problemas de CQ, verificação de materiais reciclados e revisão de atribuição de picos apoiada pela literatura.
Erros comuns
- Tratar uma banda isolada como prova de um material sem verificar pelo menos um ou dois picos de suporte.
- Ignorando sobreposição: vários grupos funcionais podem contribuir próximo ao mesmo número de onda.
- Ignorar a validação quando aditivos, misturas, oxidação ou contaminação podem distorcer o espectro.
Conselho de verificação
Quando a ambiguidade persistir, valide a hipótese com DSC, GC-MS ou TGA, especialmente para misturas, amostras degradadas e polímeros carregados.
Literatura por trás destas atribuições
-
Adsorbed carbon monoxide confiança 1,0
“In a flow 2 cm-1 of this reaction mixture, a constant intensity of the overlapping adsorbed CO at about 2340 appeared briefly at around 1 2 cm-1 bands at 2112 and 2090 min.”
In Situ Transient FTIR and XANES Studies of the Evolution of Surface Species in CO Oxidation on Au/TiO<sub>2</sub> DOI: 10.1021/jp0568733 -
Azide confiança 1,0
“Regarding AASC, a strong peak at 2112 cm-1 was assigned to the azide group.”
Synthesis and Antioxidant Activity of Cationic 1,2,3-Triazole Functionalized Starch Derivatives DOI: 10.3390/polym12010112 -
confiança 0,9
“Explicit assignment: '2112-2114cm-1 observed for the band of CO adsorbed on isolated Pt atoms'”
Litke 等 - 2019 - Interfacial charge transfer in Pt-loaded TiO2 P25 DOI: 10.1016/j.jphotochem.2018.10.023 -
confiança 0,8
“Text states: 'The existence of CO is verified by bands at 2112'”
Fabrication and Characterization of Lignin/Dendrimer Electrospun Blended Fiber Mats DOI: 10.3390/molecules26030518
Tem um espectro com esta banda?
Carregue seu espectro FTIR e obtenha um relatório de interpretação completo — atribuições de picos com citações da literatura, correspondências de biblioteca e uma cadeia de evidências com nível de confiança — em segundos.