What absorbs at 2070 cm⁻¹ in an FTIR spectrum?
A band near 2070 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
빠른 답변
A band near 2070 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
가능한 작용기 할당
| 작용기 | 지원 사실 | 인용 출처 | 최고 신뢰도 |
|---|---|---|---|
| Adsorbed carbon monoxide | 2 | 2 | 1.0 |
| C=n | 1 | 1 | 1.0 |
| Carbon dioxide | 1 | 1 | 1.0 |
| Thiocyanate | 1 | 1 | 0.8 |
순위는 단일 권위 규칙이 아닌 축적된 문헌 증거를 반영합니다. 항상 샘플 상황에 대해 확인하세요.
스펙트럼 로직
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2070 cm⁻¹ is usually not enough for material identification by itself.
실제 사용
이러한 유형의 질의는 고분자 식별, 미지 플라스틱 스크리닝, QC 문제 해결, 재활용 재료 검증 및 문헌 기반 피크 할당 검토에서 일반적입니다.
일반적인 실수
- 하나의 고립된 밴드를 재료의 증거로 취급하고 최소 하나 또는 두 개의 지원 피크를 확인하지 않는 것.
- 겹침 무시: 여러 작용기가 동일한 파수 근처에서 기여할 수 있습니다.
- 첨가제, 혼합물, 산화 또는 오염이 스펙트럼을 왜곡할 수 있는 경우 검증을 건너뜁니다.
검증 조언
모호성이 남아 있는 경우, 특히 혼합물, 분해된 시료 및 충전 폴리머의 경우 DSC, GC-MS 또는 TGA로 가설을 검증하십시오.
이 할당의 배경이 되는 문헌
-
신뢰도 1.0
“Lack for 1 h at 323 K) on fresh surface (top spectrum) reveals a of oxidized Pd adsorption sites due to the reducing effect of set of vibrational features at 2070, 1980, 1931, 1504, 1463, CO also enables us to rule out the presence of carbo”
Sulfur Poisoning and Regeneration Behavior of Perovskite-Based NO Oxidation Catalysts DOI: 10.1007/s11244-016-0721-9 -
Adsorbed carbon monoxide 신뢰도 1.0
“The absorption peak observed at 2070 cm-1 is due to 0.05 linearly adsorbed CO on the Pt surface [1].”
Setup, sensitivity and application of thin electrolyte layer ATR-FTIR spectroscopy DOI: 10.1016/j.jelechem.2004.01.028 -
Adsorbed carbon monoxide 신뢰도 1.0
“cm-1), 2300-2400 625-725 carbon monoxide (CO: cm-1), 2000-2200 sulfide carbonyl (COS: double peaks at 2070;”
Kinetic analysis of the thermal decomposition of a carbon fibre-reinforced epoxy resin laminate DOI: 10.1016/j.jaap.2017.07.002 -
Carbon dioxide 신뢰도 1.0
“This result clearly indicates that the three peaks at 2041, 2021, and 2070 cm-1 are not associated with just one molecule of Co2(CO)8.”
Wang Hang 等 - 2013 - In situ FTIR study of low-pressure hydroformylatio DOI: 10.1016/S1872-2067(11)60504-4 -
C=n 신뢰도 1.0
“2070 cm-1 C=N stretch, 3000 cm-1 C-H stretch c.”
Walters 等 - 2005 - Structure of a-C N H prepared from ammonia DOI: 10.1557/JMR.2005.0423 -
신뢰도 0.9
“Band at 2070-2030 due to CO on Rh”
Structure and reactivity of Au–Rh bimetallic clusters on titanate nanowires, nanotubes and TiO2(110) DOI: 10.1016/j.cattod.2011.06.002 -
Thiocyanate 신뢰도 0.8
“Text: 'shoulder at 2070' and 'SCN-'”
Johnson 等 - 2021 - An ultrafast vibrational study of dynamical hetero DOI: 10.1063/5.0044822
이 밴드가 있는 스펙트럼이 있나요?
FTIR 스펙트럼을 업로드하면 몇 초 안에 전체 해석 보고서(문헌 인용이 포함된 피크 할당, 라이브러리 매칭, 신뢰도 평가 증거 체인)를 받을 수 있습니다.