What absorbs at 2058 cm⁻¹ in an FTIR spectrum?
A band near 2058 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Quick answer
A band near 2058 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possible functional-group assignments
| Functional group | Supporting facts | Cited sources | Top confidence |
|---|---|---|---|
| Adsorbed carbon monoxide | 1 | 1 | 1.0 |
| Boron nitrogen | 1 | 1 | 1.0 |
| Methoxy (OCH3) | 1 | 1 | 1.0 |
| Methacrylate | 1 | 1 | 1.0 |
| C-O single bond | 1 | 1 | 1.0 |
| Acetate | 1 | 1 | 1.0 |
| Thiocyanate | 1 | 1 | 0.8 |
Ranking reflects accumulated literature evidence, not a single authoritative rule. Always confirm against your sample context.
Possible materials
| Material | Supporting peaks | Overlapping groups | Cited sources |
|---|---|---|---|
| saliva | 2058, 1648, 1664 | Methacrylate, Methoxy (OCH3) | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2058 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Literature behind these assignments
-
Acetate confidence 1.0
“However, the [Fe-NO • OC-Cu B] state exhibits cm-1, only one ν(C-O)Cu at 2057 which contrasts with the multiple ν(C-O)Cu bands B B N cm-1 observed at 2058 and 2073 observed after photolysis of bo 3-CO at low temperature”
Hayashi 等 - 2009 - Accommodation of Two Diatomic Molecules in Cytochr DOI: 10.1021/bi801915r. -
Adsorbed carbon monoxide confidence 1.0
“The peak at 2058 was the strongest among 2 the aforementioned five peaks and was assigned to CO adsorbed on a single Pt atom on the terrace [27],”
High-yield synthesis of PVP-stabilized small Pt clusters by microfluidic method DOI: 10.1016/j.cattod.2011.10.008 -
Thiocyanate confidence 0.8
“Band at 2058 cm-1 attributed to thiocyanate.”
The Role of the Preanalytical Step for Human Saliva Analysis via Vibrational Spectroscopy DOI: 10.3390/metabo13030393