Oxygen heterocycle — Puncak serapan FTIR dan tugasan
Ini adalah nombor gelombang FTIR ciri di mana Oxygen heterocycle cenderung menyerap, disusun dari literatur yang diterbitkan dan disusun berdasarkan bukti sokongan. Setiap tugasan dapat dikesan ke sumber (DOI) dan disahkan silang terhadap 130,000+ spektrum rujukan dan graf pengetahuan kami.
Backed by 8 cited sources
Jawapan pantas
Oxygen heterocycle biasanya ditetapkan dengan mencari kelompok berulang puncak ciri dan bukan satu nombor tepat buku teks. Jadual di bawah menunjukkan di mana literatur paling kerap meletakkan kumpulan ini dalam FTIR, yang disusun mengikut bukti terkumpul.
Puncak FTIR ciri untuk Oxygen heterocycle
| Nombor gelombang (cm⁻¹) | Fakta sokongan | Sumber dipetik | Keyakinan tertinggi |
|---|---|---|---|
| 910 | 11 | 11 | 1.0 |
| 915 | 8 | 7 | 1.0 |
| 916 | 5 | 5 | 1.0 |
| 906 | 5 | 4 | 1.0 |
| 914 | 5 | 3 | 1.0 |
| 907 | 4 | 3 | 1.0 |
| 1250 | 4 | 3 | 1.0 |
| 913 | 3 | 3 | 1.0 |
| 905 | 3 | 3 | 1.0 |
| 830 | 3 | 3 | 1.0 |
| 820 | 3 | 3 | 1.0 |
| 1571 | 3 | 2 | 1.0 |
| 3050 | 3 | 2 | 1.0 |
| 1035 | 2 | 2 | 1.0 |
| 2922 | 2 | 2 | 1.0 |
| 1011 | 2 | 2 | 1.0 |
| 1230 | 2 | 2 | 1.0 |
| 1260 | 2 | 2 | 1.0 |
| 904 | 2 | 2 | 1.0 |
| 870 | 2 | 2 | 1.0 |
| 912 | 2 | 2 | 1.0 |
| 903 | 2 | 2 | 1.0 |
| 902 | 2 | 2 | 1.0 |
| 1218 | 2 | 2 | 1.0 |
| 1180 | 2 | 2 | 1.0 |
| 997 | 2 | 2 | 1.0 |
| 918 | 2 | 2 | 1.0 |
| 1186 | 2 | 2 | 1.0 |
| 875 | 2 | 2 | 1.0 |
| 758 | 2 | 2 | 0.9 |
Menunjukkan 30 puncak terbaik disokong daripada 170 jumlah untuk Oxygen heterocycle.
Bahan yang mungkin
Logik spektrum
Tugasan kumpulan berfungsi menjadi lebih yakin apabila beberapa jalur yang dijangkakan muncul bersama. Gunakan halaman ini untuk mencari puncak yang paling disokong, kemudian sahkan bahawa sampel yang sama menunjukkan corak yang koheren dan bukannya satu hit terpencil.
Penggunaan dunia sebenar
Halaman-halaman ini berguna untuk analisis bahan yang tidak diketahui, penjelasan puncak dalam laporan, penyelesaian masalah polimer, dan mengesahkan sama ada keluarga bahan calon adalah boleh dipercayai secara kimia.
Kesilapan biasa
- Menggunakan satu halaman kumpulan berfungsi sebagai keputusan bahan lengkap tanpa memeriksa spektrum yang lain.
- Dengan menganggap jalur yang paling kuat sentiasa menjadi yang paling diagnostik.
- Melupakan bahawa pemprosesan, bahan tambahan, penuaan, dan campuran boleh mengalihkan atau melebarkan puncak yang dijangkakan.
Nasihat pengesahan
Gunakan DSC, GC-MS, atau TGA apabila beberapa keluarga bahan berkongsi jalur yang serupa atau apabila kesan campuran menyebabkan tugasan FTIR tidak pasti.
Literatur di sebalik penetapan ini
-
810 cm⁻¹ keyakinan 1.0
“It is worth mentioning that the peak at 810 (figure 8(c)) which corresponds to 27 28 the epoxy ring in AESO structure has gradually become weaker and almost disappeared after 30”
Ataei 等 - 2020 - Electrosprayed PMMA microcapsules containing green DOI: 10.1088/1361-665X/ab9754 -
1700 cm⁻¹ keyakinan 1.0
“It is rather interesting to detect a carboxyl group's peak (C=O) at 1700 cm-1, associated with an oleic acid epoxide, apparently decreased after polymerization.”
Bahadi 等 - 2021 - Synthesis and Characterization of Green Biodegrada DOI: 10.33263/BRIAC116.1435914371 -
913 cm⁻¹ keyakinan 1.0
“The FTIR of cured epoxy shows ring opening by the disappearance of oxirane ring peak at 913 whereas X-ray diffraction shows its amorphous phase in the cured state.”
Influence of amine‐terminated additives on thermal and mechanical properties of diglycidyl ether of bisphenol A (DGEBA) cured epoxy DOI: 10.1002/app.48404 -
1738 cm⁻¹ keyakinan 1.0
“Appearance of new peak at 1738 corresponding to carbonyl ester stretch indicates possible esterification reaction of carboxylic anion with highly strained epoxy ring leading to ionized epoxide (shown in Fig.”
Mechanism and Kinetics of Curing of Diglycidyl Ether of Bisphenol A (DGEBA) Resin by Chitosan DOI: 10.1002/pen.24463 -
916 cm⁻¹ keyakinan 1.0
“LLM confirmed rule peak-group candidate”
Barbadillo 等 - 2003 - Study of a curing reaction of an epoxy resin DOI: 10.4028/www.scientific.net/MSF.426-432.2163 -
1300 cm⁻¹ keyakinan 1.0
“The cm(cid:3)1intheC-matandcomposite lackofamajorpeakaround1300 indicatesthat the DWNTstarted with few defects and the curingof the epoxy did not damage them.”
Probing deformation of double-walled carbon nanotube (DWNT)/epoxy composites using FTIR and Raman techniques DOI: 10.1016/j.compscitech.2010.04.025 -
875 cm⁻¹ keyakinan 1.0
“cm-1 The existence of the epoxide ring in the purified ENR-25 is shown by peak at 875 due to half ring stretching of the epoxide while the full ring stretching is at 1234 cm-1 [9].”
Dahham 等 - 2018 - The Influences of Zirconium Dioxide on ENR-25ZrO2 DOI: 10.1088/1742-6596/1019/1/012055 -
1717 cm⁻¹ keyakinan 1.0
“The peak at 1486 cm-1 of ODA belongs to the C-H bend, and it moves to 1464 cm-1 in cm-1 cm-1 The bands at 1717 and 1060 corresponding to carboxyl and epoxide were weakened functionalized GO.”
Daud 等 - 2017 - Functionalizing Graphene Oxide with Alkylamine by DOI: 10.3390/nano7060135
Lihat Oxygen heterocycle dalam spektrum anda sendiri
Muat naik spektrum FTIR anda dan dapatkan laporan tafsiran penuh — tugasan puncak dengan petikan literatur, padanan perpustakaan, dan analisis berasaskan literatur — dalam beberapa saat.