What absorbs at 578 cm⁻¹ in an FTIR spectrum?
Ивица близо до 578 cm⁻¹ може да сочи към няколко функционални групи. По-долу са най-вероятните присвоявания, подредени по количеството публикувани доказателства, които ги подкрепят — всяко едно проследимо до литература (DOI) и кръстосано валидирано спрямо нашите 130 000+ референтни спектъра и графика на знанията.
Backed by 8 cited sources
Бърз отговор
A band near 578 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Възможни определяния на функционални групи
| Функционална група | Подкрепящи факти | Цитирани източници | Най-висока достоверност |
|---|---|---|---|
| Alkyl C-H | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Silicon (Si) | 1 | 1 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 0,9 |
| Carboxyl (COOH) | 1 | 1 | 0,9 |
| Phosphate (PO4) | 1 | 1 | 0,8 |
Класирането отразява натрупаните литературни доказателства, а не единично авторитетно правило. Винаги потвърждавайте спрямо контекста на вашата проба.
Възможни материали
| Материал | Подкрепящи пикове | Припокриващи се групи | Цитирани източници |
|---|---|---|---|
| SiO2 | 578, 1739, 699 | Alkyl C-H, Silicon (Si), Hydroxyl (O-H) | 1 |
| CuO | 578, 453, 1000 | Hydroxyl (O-H) | 1 |
| Fe2O3 | 578, 1130, 1631 | Hydroxyl (O-H), Alkyl C-H | 1 |
| PVC | 578, 834, 1195 | Alkyl C-H, Hydroxyl (O-H) | 1 |
Материалите се показват само когато същата литературна база поддържа тази лента и поне един допълнителен характерен пик.
Логика на спектъра
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 578 cm⁻¹ is usually not enough for material identification by itself.
Използване в реални условия
Този тип заявка е често срещана при идентификация на полимери, скрининг на неизвестни пластмаси, отстраняване на проблеми с качеството, проверка на рециклирани материали и преглед на приписване на пикове, подкрепено с литература.
Често срещани грешки
- Разглеждане на една изолирана лента като доказателство за материал, без да се проверяват поне един или два подкрепящи пика.
- Пренебрегване на припокриване: множество функционални групи могат да допринасят близо до едно и също вълново число.
- Пропускане на валидиране, когато добавки, смеси, окисление или замърсяване могат да изкривят спектъра.
Съвет за проверка
Когато остава неяснота, потвърдете хипотезата с DSC, GC-MS или TGA, особено за смеси, деградирани проби и пълнени полимери.
Литература зад тези определяния
-
достоверност 1,0
“The bands at 475 was ascribed to CuO cm-1 Fe3+ O2vibration, whereas that at 578 corresponding to the and bonds stretching in the FeO 4 Page 5/33 tetrahedron (Hao et al.”
Bousalah 等 - 2022 - Enhanced reactivity of the CuO-Fe2O3 intimate hete DOI: 10.21203/rs.3.rs-1276158/v1 -
Alkene (C=C) достоверност 1,0
“The -CH=CH2 characteristic absorption peak -CH=CH stretching vibration peak of Fe-Ois 578 The characteristic absorption 2 cm-1 at 1630 cm-1 of the synthesized monomer GMA disappeared after the preparation of the peak at 1630 of the synthesi”
Design and Preparation of Imidazole Ionic Liquid-Based Magnetic Polymers and Its Adsorption on Sunset Yellow Dye DOI: 10.3390/ma15072628 -
достоверност 1,0
“Si or Al, symmetric stretching vibration of CO at about 2 cm-1, 873 symmetrically stretching vibration of Si-O at 698 cm-1,bendingvibrationofSi-O-Alat578cm-1 andin-plane cm-1 bending vibration of Si-O-Si and O-Si-O at 453 respectively as in”
Meng 等 - 2021 - Effects of load types and critical molar ratios on DOI: 10.1515/rams-2021-0019 -
Silicon (Si) достоверност 1,0
“The Si2843 777 2922 1146 2978 1032 3753 3461 578 cm-1 O-Si bending mode appears at 446 (435) [49].”
Rangelova 等 - 2011 - MethylcelluloseSiO2 hybrids sol-gel preparation DOI: 10.2478/s11532-010-0123-y -
Hydroxyl (O-H) достоверност 1,0
“2 cm-1 cm-1 obtained for the data acquired from DSC or FTIR 681.8 (C-Cl stretching), 577.6 (O-H bending (Table 2).”
Principal component and cluster analyses as supporting tools for co-crystals detection DOI: 10.1007/s10973-017-6436-8 -
Alkyl C-H достоверност 1,0
“The correlation and (c), the FITR and NMR bands were strongly correlated with intensities of aromatic carbons with other factors were much XPS band at 577.6 eV that represents the signal of reduced higher than that of aliphatic carbons, whi”
A novel method of three-dimensional hetero-spectral correlation analysis for the fingerprint identification of humic acid functional groups for hexavalent chromium retention DOI: 10.1039/c7ra12146f -
Carboxyl (COOH) достоверност 0,9
“Explicit assignment in text.”
Jonynaite 等 - 2010 - Spectroscopic analysis of blue cobalt smalt pigmen DOI: 10.1016/j.vibspec.2009.12.005 -
достоверност 0,9
“Text: 'as(CF3) ... peaks at ... 578'”
Ramesh 和 Yi - 2009 - FTIR spectra of plasticized high molecular weight DOI: 10.1007/s11581-008-0279-z
Имате спектър с тази лента?
Качете вашия FTIR спектър и получете пълен отчет за интерпретация — определяне на пикове с литературни цитати, съвпадения с библиотека и верига от доказателства с оценка на достоверността — за секунди.