What absorbs at 507 cm⁻¹ in an FTIR spectrum?
A band near 507 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Mabilis na sagot
A band near 507 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mga posibleng pagtatalaga ng functional-group
| Grupong functional | Mga sumusuportang katotohanan | Mga nasiping sanggunian | Pinakamataas na kumpiyansa |
|---|---|---|---|
| Metal oxygen | 2 | 2 | 1.0 |
| Silicon hydride | 1 | 1 | 1.0 |
| Aromatic ring | 1 | 1 | 1.0 |
| C c single bond | 1 | 1 | 1.0 |
Ang pagraranggo ay sumasalamin sa naipon na ebidensya ng literatura, hindi isang solong awtoritatibong tuntunin. Palaging kumpirmahin laban sa konteksto ng iyong sample.
Mga posibleng materyales
| Materyal | Sumusuportang mga peak | Mga overlapping na grupo | Mga nasiping sanggunian |
|---|---|---|---|
| ZnO | 507, 1400, 3430 | Metal oxygen | 1 |
Ang mga materyales ay ipinapakita lamang kapag ang parehong literatura pool ay sumusuporta sa banda na ito at hindi bababa sa isang karagdagang katangian na tuktok.
Logic ng spectrum
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 507 cm⁻¹ is usually not enough for material identification by itself.
Paggamit sa totoong mundo
Ang uri ng query na ito ay karaniwan sa pagtukoy ng polymer, screening ng hindi kilalang plastic, pag-troubleshoot ng QC, pag-verify ng recycled na materyal, at pagsusuri ng pagtatalaga ng peak na may suporta ng literatura.
Mga karaniwang pagkakamali
- Pagtrato sa isang nakahiwalay na banda bilang patunay ng isang materyal nang hindi sinusuri ang hindi bababa sa isa o dalawang sumusuportang peak.
- Hindi pinapansin ang overlap: maraming functional group ang maaaring mag-ambag malapit sa parehong wavenumber.
- Pag-laktaw sa pagpapatunay kapag ang mga additives, blends, oxidation, o contamination ay maaaring mag-distort ng spectrum.
Payo sa pagpapatunay
Kapag nananatili ang kalabuan, patunayan ang hypothesis gamit ang DSC, GC-MS, o TGA, lalo na para sa mga blend, degraded na sample, at filled polymers.
Literatura sa likod ng mga pagtatalagang ito
-
kumpiyansa 1.0
“But the sample annealed at 800 has weak peak emerged at 507 which is related to nitrogen related local vibration as reported in the reference [26].”
Enhancement of Al-N co-dopant solubility in ZnO by high temperature thermal annealing DOI: 10.1016/j.ceramint.2018.10.005 -
kumpiyansa 1.0
“A around 507 cm-1 is clearly observed in Figure 2 and can be attributed to Au and Bu vibracm-1”
Surface Morphology and Optical Properties of Hafnium Oxide Thin Films Produced by Magnetron Sputtering DOI: 10.3390/ma16155331 -
C c single bond kumpiyansa 1.0
“506 In situ FTIR spectroscopy has revealed that the three 507 472 to a C-C stretching of benzenoid rings.”
Benyoucef 等 - 2005 - Synthesis and in situ MRS characterization of cond DOI: 10.1016/j.eurpolymj.2004.10.047 -
Silicon hydride kumpiyansa 1.0
“cm(cid:0) C-- 1 C stretching peak at 1640 attenuated or disappeared, whereas On the FTIR spectrum for the activated CoCr surface, the disappearance (CoCr-OH-Si45-GO12h, emerged in all incubated multilayer systems of chromium oxide (III) rel”
Covalent immobilization of graphene oxide on biomedical grade CoCr alloy by an improved multilayer system assembly via Silane/GO bonding DOI: 10.1016/j.matchemphys.2022.126296 -
Metal oxygen kumpiyansa 1.0
“Pressure (MPa) 0.1 122.38 305.34 399.23 517.59 606.87 (cm-1) 432.33 433.02 433.20 433.50 433.50 434.83 M-O vibrational peak (cm-1) AlIV-O-Si 507.27 507.43 507.80 508.46 508.13 509.46 vibrational peak (cm-1)”
The Behavior of Water in Orthoclase Crystal and Its Implications for Feldspar Alteration DOI: 10.3390/cryst12081042 -
Metal oxygen kumpiyansa 0.9
“Fe-O stretching and bending”
Jalandhara 等 - 2016 - Effect of Sintering Temperature on the Optical Pro DOI: 10.1063/1.4946488 -
kumpiyansa 0.8
“Explicit assignment in text.”
Phytochemical screening, polyphenols, flavonoids and tannin content, antioxidant activities and FTIR characterization of Marrubium vulgare L. from 2 different localities of Northeast of Morocco DOI: 10.1016/j.heliyon.2020.e05609 -
kumpiyansa 0.6
“Text: 'at 1004, 825, and 507'”
Characterisation of the Bioactivity and the Solubility of a New Root Canal Sealer DOI: 10.1016/j.identj.2023.04.003
May spectrum ka ba na may ganitong band?
I-upload ang iyong FTIR spectrum at makakuha ng buong interpretasyon na ulat — mga pagtatalaga ng peak na may mga pagsipi ng literatura, pagtutugma ng library, at isang kadena ng ebidensya na may rating ng kumpiyansa — sa loob ng ilang segundo.