What absorbs at 507 cm⁻¹ in an FTIR spectrum?
A band near 507 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Stutt svar
A band near 507 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögulegar úthlutun virkra hópa
| Virkur hópur | Stuðningsstaðreyndir | Tilvitnuð heimildir | Mesta öryggi |
|---|---|---|---|
| Metal oxygen | 2 | 2 | 1,0 |
| Silicon hydride | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| C c single bond | 1 | 1 | 1,0 |
Röðun endurspeglar uppsöfnuð ritrýnisgögn, ekki eina valdboðsreglu. Staðfestu alltaf í samhengi við sýnið þitt.
Möguleg efni
| Efni | Stuðningstindar | Skarast hópar | Tilvitnuð heimildir |
|---|---|---|---|
| ZnO | 507, 1400, 3430 | Metal oxygen | 1 |
Efni birtast aðeins þegar sama bókmenntasafn styður þessa band og að minnsta kosti einn viðbótar einkennandi hámark.
Rófrök
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 507 cm⁻¹ is usually not enough for material identification by itself.
Raunveruleg notkun
Þessi tegund fyrirspurna er algeng við auðkenningu fjölliða, skimun óþekktra plasttegunda, bilanaleit í gæðaeftirliti, staðfestingu endurunnins efnis og bókmenntabakkaða endurskoðun á hápunktum.
Algeng mistök
- Meðhöndla eina einangraða öldulengd sem sönnun á efni án þess að athuga að minnsta kosti einn eða tvo stuðningstoppa.
- Hunsa skörun: mörg virkir hópar geta lagt sitt af mörkum nálægt sömu bylgjutölunni.
- Að sleppa staðfestingu þegar aukefni, blöndur, oxun eða mengun geta brenglað litrófið.
Staðfestingarráðgjöf
Þegar tvíræðni er eftir, staðfestu tilgátuna með DSC, GC-MS eða TGA, sérstaklega fyrir blöndur, niðurbrotin sýni og fylltar fjölliður.
Ritlist á bak við þessar úthlutanir
-
öryggi 1,0
“But the sample annealed at 800 has weak peak emerged at 507 which is related to nitrogen related local vibration as reported in the reference [26].”
Enhancement of Al-N co-dopant solubility in ZnO by high temperature thermal annealing DOI: 10.1016/j.ceramint.2018.10.005 -
öryggi 1,0
“A around 507 cm-1 is clearly observed in Figure 2 and can be attributed to Au and Bu vibracm-1”
Surface Morphology and Optical Properties of Hafnium Oxide Thin Films Produced by Magnetron Sputtering DOI: 10.3390/ma16155331 -
C c single bond öryggi 1,0
“506 In situ FTIR spectroscopy has revealed that the three 507 472 to a C-C stretching of benzenoid rings.”
Benyoucef 等 - 2005 - Synthesis and in situ MRS characterization of cond DOI: 10.1016/j.eurpolymj.2004.10.047 -
Silicon hydride öryggi 1,0
“cm(cid:0) C-- 1 C stretching peak at 1640 attenuated or disappeared, whereas On the FTIR spectrum for the activated CoCr surface, the disappearance (CoCr-OH-Si45-GO12h, emerged in all incubated multilayer systems of chromium oxide (III) rel”
Covalent immobilization of graphene oxide on biomedical grade CoCr alloy by an improved multilayer system assembly via Silane/GO bonding DOI: 10.1016/j.matchemphys.2022.126296 -
Metal oxygen öryggi 1,0
“Pressure (MPa) 0.1 122.38 305.34 399.23 517.59 606.87 (cm-1) 432.33 433.02 433.20 433.50 433.50 434.83 M-O vibrational peak (cm-1) AlIV-O-Si 507.27 507.43 507.80 508.46 508.13 509.46 vibrational peak (cm-1)”
The Behavior of Water in Orthoclase Crystal and Its Implications for Feldspar Alteration DOI: 10.3390/cryst12081042 -
Metal oxygen öryggi 0,9
“Fe-O stretching and bending”
Jalandhara 等 - 2016 - Effect of Sintering Temperature on the Optical Pro DOI: 10.1063/1.4946488 -
öryggi 0,8
“Explicit assignment in text.”
Phytochemical screening, polyphenols, flavonoids and tannin content, antioxidant activities and FTIR characterization of Marrubium vulgare L. from 2 different localities of Northeast of Morocco DOI: 10.1016/j.heliyon.2020.e05609 -
öryggi 0,6
“Text: 'at 1004, 825, and 507'”
Characterisation of the Bioactivity and the Solubility of a New Root Canal Sealer DOI: 10.1016/j.identj.2023.04.003
Ertu með róf með þessu bandi?
Hladdu upp FTIR-rófinu þínu og fáðu fulla túlkunarskýrslu — toppúthlutun með tilvitnunum í ritrýni, bókasamsvörun og sönnunarkeðju með öryggismati — á nokkrum sekúndum.