What absorbs at 466 cm⁻¹ in an FTIR spectrum?
A band near 466 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
빠른 답변
A band near 466 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
가능한 작용기 할당
| 작용기 | 지원 사실 | 인용 출처 | 최고 신뢰도 |
|---|---|---|---|
| Silicon-oxygen (Si-O) | 9 | 8 | 1.0 |
| Silicon (Si) | 4 | 4 | 1.0 |
| Siloxane (Si-O-Si) | 4 | 4 | 1.0 |
| Ring structure | 1 | 1 | 1.0 |
| Secondary amine | 1 | 1 | 1.0 |
| C n single bond | 1 | 1 | 1.0 |
| Amide | 1 | 1 | 1.0 |
| Alkyl C-H | 1 | 1 | 1.0 |
| Hydroxyl (O-H) | 1 | 1 | 1.0 |
| Metal oxygen | 1 | 1 | 0.9 |
순위는 단일 권위 규칙이 아닌 축적된 문헌 증거를 반영합니다. 항상 샘플 상황에 대해 확인하세요.
가능한 재료
| 재료 | 지원 피크 | 겹치는 그룹 | 인용 출처 |
|---|---|---|---|
| SiO2 | 466, 1739, 699 | Silicon-oxygen (Si-O), Silicon (Si), Siloxane (Si-O-Si) | 2 |
| Silica | 466, 1100, 1080 | Silicon-oxygen (Si-O), Silicon (Si), Siloxane (Si-O-Si) | 1 |
동일한 문헌 풀이 이 밴드와 하나 이상의 추가 특징 피크를 지원하는 경우에만 물질이 표시됩니다.
스펙트럼 로직
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 466 cm⁻¹ is usually not enough for material identification by itself.
실제 사용
이러한 유형의 질의는 고분자 식별, 미지 플라스틱 스크리닝, QC 문제 해결, 재활용 재료 검증 및 문헌 기반 피크 할당 검토에서 일반적입니다.
일반적인 실수
- 하나의 고립된 밴드를 재료의 증거로 취급하고 최소 하나 또는 두 개의 지원 피크를 확인하지 않는 것.
- 겹침 무시: 여러 작용기가 동일한 파수 근처에서 기여할 수 있습니다.
- 첨가제, 혼합물, 산화 또는 오염이 스펙트럼을 왜곡할 수 있는 경우 검증을 건너뜁니다.
검증 조언
모호성이 남아 있는 경우, 특히 혼합물, 분해된 시료 및 충전 폴리머의 경우 DSC, GC-MS 또는 TGA로 가설을 검증하십시오.
이 할당의 배경이 되는 문헌
-
신뢰도 1.0
“The [18] located the spectra region at 466 cm-1 and attributed it to the Ti-C vibration.”
Effect of Microstructural and Tribological Behaviors of Sputtered Titanium Carbide Thin Film on Copper Substrate DOI: 10.3390/ma16010174 -
Hydroxyl (O-H) 신뢰도 1.0
“465 PC1, PCB1), (P, PC2, PCB2), (P, PC3, PCB3) and (P, OPS, MRP, RF) predominantly showed 466 characteristic peaks of vibrationally active chemical groups those likely corresponding to hydroxyl USC (cm-1).”
Evaluation of structural integrity and functionality of commercial pectin based edible films incorporated with corn flour, beetroot, orange peel, muesli and rice flour DOI: 10.1016/j.foodhyd.2019.01.022 -
Silicon (Si) 신뢰도 1.0
“The absorption bands of RHA at cm-1 cm-1 466 is ascribed to Si-O distortion, 800 corresponds to Si-O bending, and Si-O-Si stretching appeared cm23.”
Rice husk derived Aminated Silica for the efficient adsorption of different gases DOI: 10.1038/s41598-020-76460-0 -
신뢰도 1.0
“The absorption peak at 795 was documented in the Si-O-Si group, cm-1 and the detected peak was 466 in the Si-O-Si group [51,52].”
Sustainable Remedy Waste to Generate SiO2 Functionalized on Graphene Oxide for Removal of U(VI) Ions DOI: 10.3390/su14052699 -
Silicon-oxygen (Si-O) 신뢰도 1.0
“The absorption bands at 1097, 1037, 802 and 774 on cm-1 the IR spectra of RHA and WG are assigned to the O-Si-O in the SiO tetrahedron and the band at 466 is”
Lancellotti 等 - 2015 - Geopolymers An option for the valorization of inc DOI: 10.1016/j.ceramint.2014.10.008 -
Silicon-oxygen (Si-O) 신뢰도 1.0
“The bands at around 466 cm-1 for FA-1 and FA-2 are connected with the bending vibrations of O-Si-O present in the silicate tetrahedron [31].”
Structural Characterizations of Aluminosilicates in Two Types of Fly Ash Samples from Shanxi Province, North China DOI: 10.3390/min9060358 -
신뢰도 1.0
“The Al-O-Si bending band appeared at 520 cm-1 and Si-O-Si bending at 466 cm-1 [63].”
The Antimicrobial Properties of Modified Pharmaceutical Bentonite with Zinc and Copper DOI: 10.3390/pharmaceutics13081190 -
신뢰도 1.0
“For the test sample, unlike the samples from the calibration set, the Si-O (SiO 2) strain cm-1 vibration absorption band at 466 was noted, which also corresponds to a relatively”
Identification of the Elemental Composition of Granulated Blast Furnace Slag by FTIR-Spectroscopy and Chemometrics DOI: 10.3390/pr10112166
이 밴드가 있는 스펙트럼이 있나요?