What absorbs at 401 cm⁻¹ in an FTIR spectrum?
A band near 401 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 7 cited sources
Schnelle Antwort
A band near 401 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| N h | 5 | 5 | 1,0 |
| Secondary amine | 4 | 4 | 1,0 |
| N-O bond | 2 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Ammonium | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 0 | 1,0 |
| Hydroxyl (O-H) | 1 | 0 | 1,0 |
| N n bond | 1 | 0 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 401 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
N h Vertrauen 1,0
“the peak at 401.2 4+ eV corresponds to NH in the APP.”
Liang 等 - 2020 - Thermal Kinetics of a Lignin-Based Flame Retardant DOI: 10.3390/polym12092123 -
Vertrauen 1,0
“The weak peak at 401.1 eV is indicative of the presence of terminal amino functional group, originating from the incomplete”
Dual Roles of [NCN]2- on Anatase TiO2: A Fully Occupied Molecular Gap State for Direct Charge Injection into the Conduction Band and an Interfacial Mediator for the Covalent Formation of Heterostructured g-C3N4/a-TiO2 Nanocomposite DOI: 10.1016/j.apcatb.2020.119036 -
Ammonium Vertrauen 1,0
“In this investigation, a novel compound characteristic peak at 401.36 eV corresponding to the -NH3?.”
Synthesis of a novel compound based on chitosan and ammonium polyphosphate for flame retardancy applications DOI: 10.1007/s10570-019-02671-y -
Metal oxygen Vertrauen 1,0
“Figure 6b shows that the water contact 2 N-C 15.2° peaks at 400.7 eV were assigned to the bond, suggesting angle of APTMS-TiO 2@SiO was decreased to and that 2 126.2°”
Wang 等 - 2023 - Surface-Modified TiO2@SiO2 Nanocomposites for Enha DOI: 10.1021/acsomega.3c02679 -
Vertrauen 1,0
“The peaks at 401.0 and 404.6 eV are attributed to the amino group (C-N-H) the graphitic N.”
Underlying Mechanisms of Reductive Amination on Pd-Catalysts: The Unique Role of Hydroxyl Group in Generating Sterically Hindered Amine DOI: 10.3390/ijms23147621 -
N h Vertrauen 1,0
“In bonds), 400.43 (NH contrast, CoPc-immobilized GO showed the shifting of bands and a considerable intensity enhancement of the peak at 400.69 eV due to the electron-withdrawing effect of GO (Fig-”
Cobalt Phthalocyanine Immobilized on Graphene Oxide: An Efficient Visible-Active Catalyst for the Photoreduction of Carbon Dioxide DOI: 10.1002/chem.201304189 -
Secondary amine Vertrauen 1,0
“BH (Figure For nylon 6-NH, vibrations of amide I and 401.0 eV attributed to the secondary amine and the new 3”
Yan 等 - 2022 - Functionalized Nylon 6 Fabric as an Efficient and DOI: 10.1021/acsomega.2c03401
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.