What absorbs at 3113 cm⁻¹ in an FTIR spectrum?
A band near 3113 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Resposta rápida
A band near 3113 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possíveis atribuições de grupos funcionais
| Grupo funcional | Fatos de suporte | Fontes citadas | Maior confiança |
|---|---|---|---|
| Alkyl C-H | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
| Secondary amine | 1 | 1 | 1,0 |
| C n single bond | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
A classificação reflete a evidência acumulada da literatura, não uma única regra autoritária. Sempre confirme com o contexto da sua amostra.
Lógica do espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3113 cm⁻¹ is usually not enough for material identification by itself.
Uso no mundo real
Este tipo de consulta é comum em identificação de polímeros, triagem de plásticos desconhecidos, solução de problemas de CQ, verificação de materiais reciclados e revisão de atribuição de picos apoiada pela literatura.
Erros comuns
- Tratar uma banda isolada como prova de um material sem verificar pelo menos um ou dois picos de suporte.
- Ignorando sobreposição: vários grupos funcionais podem contribuir próximo ao mesmo número de onda.
- Ignorar a validação quando aditivos, misturas, oxidação ou contaminação podem distorcer o espectro.
Conselho de verificação
Quando a ambiguidade persistir, valide a hipótese com DSC, GC-MS ou TGA, especialmente para misturas, amostras degradadas e polímeros carregados.
Literatura por trás destas atribuições
-
Amide confiança 1,0
“UV-light irradiation The FTIR (Figure 1b) of TPyP showed stretching vibrations of an aromatic amine The FTIR (Figure 1b) of TPyP showed stretching vibrations of an aromatic amine group cm-1, group (N-H) and the bending of aromatic amine (C-”
Graphene Oxide-Gold Nanorods Nanocomposite-Porphyrin Conjugate as Promising Tool for Cancer Phototherapy Performance DOI: 10.3390/ph14121295 -
confiança 1,0
“Thus, chymotrypsin-drug association showed two new peaks at 3176cm-1 and3113cm-1, at 3176 cm-1 and 3113 cm-1, attributed to N-H stretching vibration.”
In Vitro Interaction of Doxorubicin-Loaded Silk Sericin Nanocarriers with MCF-7 Breast Cancer Cells Leads to DNA Damage DOI: 10.3390/polym13132047 -
Alkyl C-H confiança 1,0
“Explicit assignment in text: 'cm-1 ((cid:1)C(5)-H) ((cid:1)C(6)-H). being 3113'”
Rozenberg 等 - 2004 - Low temperature FTIR spectroscopy and hydrogen bon DOI: 10.1016/S1386-1425(03)00251-8
Tem um espectro com esta banda?
Carregue seu espectro FTIR e obtenha um relatório de interpretação completo — atribuições de picos com citações da literatura, correspondências de biblioteca e uma cadeia de evidências com nível de confiança — em segundos.