What absorbs at 2152 cm⁻¹ in an FTIR spectrum?
A band near 2152 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Быстрый ответ
A band near 2152 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Silicon hydride | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Adsorbed carbon monoxide | 1 | 1 | 1,0 |
| Nitrile | 1 | 1 | 0,9 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Возможные материалы
| Материал | Поддерживающие пики | Перекрывающиеся группы | Цитируемые источники |
|---|---|---|---|
| TiO2 | 2152, 1700, 1093 | Metal oxygen, Hydroxyl (O-H) | 1 |
Материалы отображаются только при поддержке данной полосы и хотя бы одного дополнительного характеристического пика из того же литературного пула.
Логика спектра
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2152 cm⁻¹ is usually not enough for material identification by itself.
Использование в реальных условиях
Такой тип запроса распространен при идентификации полимеров, скрининге неизвестных пластиков, устранении неполадок в контроле качества, проверке переработанных материалов и анализе отнесения пиков на основе литературы.
Распространенные ошибки
- Рассмотрение одной изолированной полосы как доказательства материала без проверки хотя бы одного или двух поддерживающих пиков.
- Игнорирование перекрытия: несколько функциональных групп могут вносить вклад вблизи одного и того же волнового числа.
- Пропуск проверки, когда добавки, смеси, окисление или загрязнение могут исказить спектр.
Рекомендации по проверке
Когда остается неоднозначность, проверьте гипотезу с помощью DSC, GC-MS или TGA, особенно для смесей, деградированных образцов и наполненных полимеров.
Литература, лежащая в основе этих назначений
-
Adsorbed carbon monoxide достоверность 1,0
“cm-1) other two bands at higher frequencies (2161 and 2152 required more time for complete The other two bands at higher frequencies (2161 cm-1 and 2152 cm-1) required more time for complete desorption, and for this reason they can be assig”
Atzori 等 - 2020 - Adsorption Properties of Ce-5(BDC)(7.5)(DMF)(4) MO DOI: 10.3390/inorganics8020009 -
Metal oxygen достоверность 1,0
“respect to the liquid like, which decreased concomitantly to the restoration of the bands at 3600 cm-1 These evidences allowed us to assign the 2152 band to an interaction of CO with the residual OH group still present on some Zr-O cornerst”
Braglia 等 - 2017 - Exploring structure and reactivity of Cu sites in DOI: 10.1016/j.cattod.2016.02.039 -
Hydroxyl (O-H) достоверность 1,0
“From this we can state that the cm-1, cm-1, slightly downward shifting with the coverage to 2152 is due to -OH····CO peak at 2156 complexes on the (020) and/or (110) crystalline planes of the multiwalled titanate nanotubes, in data.48 agree”
Cesano 等 - 2010 - Designing TiO2 Based Nanostructures by Control of DOI: 10.1021/jp9087207 -
Silicon hydride достоверность 1,0
“In contrast, for Du1800-Pd precursor (Figure 6b), the intensity of cm-1), cm-1), cm-1), absorption bands corresponding to N-H (3343 C-H (2960 Si-H (2152 cm-1), -COO-1”
Porous Silicon Oxycarbonitride Ceramics with Palladium and Pd2Si Nanoparticles for Dry Reforming of Methane DOI: 10.3390/polym14173470 -
Nitrile достоверность 0,9
“Explicit assignment: C≡N stretching frequency at 2152 cm⁻¹”
Gerber 和 Erasmus - 2018 - Electronic effects of metal hexacyanoferrates An DOI: 10.1016/j.matchemphys.2017.09.029
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.