What absorbs at 2152 cm⁻¹ in an FTIR spectrum?
A band near 2152 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Risposta rapida
A band near 2152 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Silicon hydride | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Adsorbed carbon monoxide | 1 | 1 | 1,0 |
| Nitrile | 1 | 1 | 0,9 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Materiali possibili
| Materiale | Picchi di supporto | Gruppi sovrapposti | Fonti citate |
|---|---|---|---|
| TiO2 | 2152, 1700, 1093 | Metal oxygen, Hydroxyl (O-H) | 1 |
I materiali vengono mostrati solo quando lo stesso pool di letteratura supporta questa banda e almeno un picco caratteristico aggiuntivo.
Logica dello spettro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2152 cm⁻¹ is usually not enough for material identification by itself.
Utilizzo nel mondo reale
Questo tipo di richiesta è comune nell'identificazione dei polimeri, nello screening di plastiche sconosciute, nella risoluzione dei problemi di controllo qualità, nella verifica dei materiali riciclati e nella revisione dell'assegnazione dei picchi supportata dalla letteratura.
Errori comuni
- Trattare una banda isolata come prova di un materiale senza verificare almeno uno o due picchi di supporto.
- Ignorando la sovrapposizione: più gruppi funzionali possono contribuire vicino allo stesso numero d'onda.
- Saltare la convalida quando additivi, miscele, ossidazione o contaminazione possono distorcere lo spettro.
Consiglio di verifica
Quando permangono ambiguità, convalida l'ipotesi con DSC, GC-MS o TGA, specialmente per miscele, campioni degradati e polimeri caricati.
Letteratura dietro queste assegnazioni
-
Adsorbed carbon monoxide affidabilità 1,0
“cm-1) other two bands at higher frequencies (2161 and 2152 required more time for complete The other two bands at higher frequencies (2161 cm-1 and 2152 cm-1) required more time for complete desorption, and for this reason they can be assig”
Atzori 等 - 2020 - Adsorption Properties of Ce-5(BDC)(7.5)(DMF)(4) MO DOI: 10.3390/inorganics8020009 -
Metal oxygen affidabilità 1,0
“respect to the liquid like, which decreased concomitantly to the restoration of the bands at 3600 cm-1 These evidences allowed us to assign the 2152 band to an interaction of CO with the residual OH group still present on some Zr-O cornerst”
Braglia 等 - 2017 - Exploring structure and reactivity of Cu sites in DOI: 10.1016/j.cattod.2016.02.039 -
Hydroxyl (O-H) affidabilità 1,0
“From this we can state that the cm-1, cm-1, slightly downward shifting with the coverage to 2152 is due to -OH····CO peak at 2156 complexes on the (020) and/or (110) crystalline planes of the multiwalled titanate nanotubes, in data.48 agree”
Cesano 等 - 2010 - Designing TiO2 Based Nanostructures by Control of DOI: 10.1021/jp9087207 -
Silicon hydride affidabilità 1,0
“In contrast, for Du1800-Pd precursor (Figure 6b), the intensity of cm-1), cm-1), cm-1), absorption bands corresponding to N-H (3343 C-H (2960 Si-H (2152 cm-1), -COO-1”
Porous Silicon Oxycarbonitride Ceramics with Palladium and Pd2Si Nanoparticles for Dry Reforming of Methane DOI: 10.3390/polym14173470 -
Nitrile affidabilità 0,9
“Explicit assignment: C≡N stretching frequency at 2152 cm⁻¹”
Gerber 和 Erasmus - 2018 - Electronic effects of metal hexacyanoferrates An DOI: 10.1016/j.matchemphys.2017.09.029
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.