What absorbs at 2152 cm⁻¹ in an FTIR spectrum?
A band near 2152 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Schnelle Antwort
A band near 2152 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Silicon hydride | 1 | 1 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Metal oxygen | 1 | 1 | 1,0 |
| Adsorbed carbon monoxide | 1 | 1 | 1,0 |
| Nitrile | 1 | 1 | 0,9 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| TiO2 | 2152, 1700, 1093 | Metal oxygen, Hydroxyl (O-H) | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2152 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Adsorbed carbon monoxide Vertrauen 1,0
“cm-1) other two bands at higher frequencies (2161 and 2152 required more time for complete The other two bands at higher frequencies (2161 cm-1 and 2152 cm-1) required more time for complete desorption, and for this reason they can be assig”
Atzori 等 - 2020 - Adsorption Properties of Ce-5(BDC)(7.5)(DMF)(4) MO DOI: 10.3390/inorganics8020009 -
Metal oxygen Vertrauen 1,0
“respect to the liquid like, which decreased concomitantly to the restoration of the bands at 3600 cm-1 These evidences allowed us to assign the 2152 band to an interaction of CO with the residual OH group still present on some Zr-O cornerst”
Braglia 等 - 2017 - Exploring structure and reactivity of Cu sites in DOI: 10.1016/j.cattod.2016.02.039 -
Hydroxyl (O-H) Vertrauen 1,0
“From this we can state that the cm-1, cm-1, slightly downward shifting with the coverage to 2152 is due to -OH····CO peak at 2156 complexes on the (020) and/or (110) crystalline planes of the multiwalled titanate nanotubes, in data.48 agree”
Cesano 等 - 2010 - Designing TiO2 Based Nanostructures by Control of DOI: 10.1021/jp9087207 -
Silicon hydride Vertrauen 1,0
“In contrast, for Du1800-Pd precursor (Figure 6b), the intensity of cm-1), cm-1), cm-1), absorption bands corresponding to N-H (3343 C-H (2960 Si-H (2152 cm-1), -COO-1”
Porous Silicon Oxycarbonitride Ceramics with Palladium and Pd2Si Nanoparticles for Dry Reforming of Methane DOI: 10.3390/polym14173470 -
Nitrile Vertrauen 0,9
“Explicit assignment: C≡N stretching frequency at 2152 cm⁻¹”
Gerber 和 Erasmus - 2018 - Electronic effects of metal hexacyanoferrates An DOI: 10.1016/j.matchemphys.2017.09.029
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.