What absorbs at 884 cm⁻¹ in an FTIR spectrum?
A band near 884 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Brzi odgovor
A band near 884 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Moguće dodjele funkcionalnih skupina
| Funkcionalna skupina | Potporni dokazi | Citirani izvori | Najveća pouzdanost |
|---|---|---|---|
| Silicon-oxygen (Si-O) | 3 | 3 | 1,0 |
| Metal oxygen | 2 | 2 | 1,0 |
| Carbonate | 2 | 2 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Protein | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
Rangiranje odražava akumulirane literaturne dokaze, a ne jedno autoritativno pravilo. Uvijek provjerite u kontekstu vašeg uzorka.
Mogući materijali
| Materijal | Potporni vrhovi | Preklapajuće skupine | Citirani izvori |
|---|---|---|---|
| alumina | 884, 460, 1000 | Metal oxygen, Siloxane (Si-O-Si), Silicon-oxygen (Si-O) | 1 |
Materijali su prikazani samo kada ista literatura podržava ovu traku i barem jedan dodatni karakteristični vrh.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 884 cm⁻¹ is usually not enough for material identification by itself.
Upotreba u stvarnom svijetu
Ova vrsta upita uobičajena je u identifikaciji polimera, probiru nepoznate plastike, rješavanju problema u kontroli kvalitete, provjeri recikliranog materijala i pregledu dodjele vrhova potkrijepljenom literaturom.
Uobičajene pogreške
- Tretiranje jedne izolirane vrpce kao dokaza materijala bez provjere barem jednog ili dva podržavajuća pika.
- Zanemarivanje preklapanja: više funkcionalnih skupina može doprinositi u blizini istog valnog broja.
- Preskakanje validacije kada aditivi, mješavine, oksidacija ili kontaminacija mogu izobličiti spektar.
Savjet za provjeru
Kada nejasnoća ostane, validirajte hipotezu pomoću DSC, GC-MS ili TGA, posebno za mješavine, degradirane uzorke i punjene polimere.
Literatura iza ovih dodjela
-
pouzdanost 1,0
“659.7 CO32(cid:2) u2 Out-of-plane bending vibration of 883.7 Strong u3 929.6 Very strong Si-O asymmetric stretching vibration of silicate SO42 u3 S-O stretching vibration of 1097 Small shoulder 1114.2”
Theoretical and experimental study of structures and properties of cement paste The nanostructural aspects of C–S–H DOI: 10.1016/j.jpcs.2011.05.001 -
Ring structure pouzdanost 1,0
“Fourier transform infra-red (FTIR) analysis cm-1 confirm 3:Ce3+ cm-1 The FTIR spectra of CaSiO phosphor was recorded in the range 400 - 4000 to the functional groups presentintheobtainedsamples,Fig.2.FTIRspectrashowstrongtransmittancepeaksa”
Dhanu 等 - 2020 - Photoluminescence of mixed phase CaSiO3Ce3+ nanop DOI: 10.1016/j.ijleo.2020.165139 -
Aromatic ring pouzdanost 1,0
“9 is attributed to 1,4-disubstitution of the aromatic ring inpolyaniline.However,therearethreepeaksat884(w),854 (w)cm-1 (m), and 800 on curve 1 in Fig.”
Li 和 Mu - 2005 - The electrochemical activity of sulfonic acid ring DOI: 10.1016/j.synthmet.2004.12.015 -
Carbonate pouzdanost 1,0
“Furthermore, a closer look atthe singlet band 2-1 at 861-864 is probably due to the n ACC.15,32,33 absorption band of carbonate groups from 2-3 singlet reveals a progressive peak shift from 884 (keel), n cm(cid:2)1 887 (needles), to 888 (pl”
Long 等 - 2012 - From synthetic to biogenic Mg-containing calcites DOI: 10.1039/c2cp22453d -
pouzdanost 1,0
“The traces of the organic cm-1 materials from the PVP were at 1535 and 2787 and cm-1, are associated with Si-O stretching at 884, and 889 could be attributed to C-H bending vibrations [47, 48].”
Alibe 等 - 2019 - Effects of polyvinylpyrrolidone on structural and DOI: 10.1007/s10973-018-7874-7 -
Protein pouzdanost 1,0
“cm-1 Increase in absorption at ~884 due to alterations in phosphorylated proteins suggest that more extensive phosphorylation occurs in malignant compared to benign samples.”
ATR-FTIR spectroscopy as adjunct method to the microscopic examination of hematoxylin and eosin-stained tissues in diagnosing lung cancer DOI: 10.1371/journal.pone.0233626 -
pouzdanost 1,0
“ESI-MS molecular-ion peak 884.42, corresponding to H+ + 1H [Zn(L5) ].”
Gusev 等 - 2020 - Synthesis, Photoluminescence and Electrical Study DOI: 10.3390/ma13245698 -
pouzdanost 1,0
“The band at cm-1 δ corresponds to the sAl-O-H mode of boehmite 1,072 cm-1 and the bands at 884, 740, 621, and 479 are attributed Al-O to the bonds of boehmite (Li et al.”
Liu 等 - 2012 - Dechlorinating transformation of propachlor throug DOI: 10.1007/s11368-012-0506-0)
Imate li spektar s ovom vrpcom?
Prenesite svoj FTIR spektar i dobijte potpuno izvješće o interpretaciji — dodjele vrhova s literaturnim citatima, podudaranja knjižnice i lanac dokaza s ocjenom pouzdanosti — u sekundama.