What absorbs at 884 cm⁻¹ in an FTIR spectrum?
A band near 884 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Rychlá odpověď
A band near 884 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Možná přiřazení funkčních skupin
| Funkční skupina | Podpůrná fakta | Citované zdroje | Nejvyšší spolehlivost |
|---|---|---|---|
| Silicon-oxygen (Si-O) | 3 | 3 | 1,0 |
| Metal oxygen | 2 | 2 | 1,0 |
| Carbonate | 2 | 2 | 1,0 |
| Siloxane (Si-O-Si) | 1 | 1 | 1,0 |
| Protein | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
Pořadí odráží nahromaděné literární důkazy, nikoli jediné autoritativní pravidlo. Vždy potvrďte v kontextu vašeho vzorku.
Možné materiály
| Materiál | Podpůrné píky | Překrývající se skupiny | Citované zdroje |
|---|---|---|---|
| alumina | 884, 460, 1000 | Metal oxygen, Siloxane (Si-O-Si), Silicon-oxygen (Si-O) | 1 |
Materiály jsou zobrazeny pouze tehdy, když stejný literární soubor podporuje tento pás a alespoň jeden další charakteristický pík.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 884 cm⁻¹ is usually not enough for material identification by itself.
Reálné použití
Tento typ dotazu je běžný při identifikaci polymerů, screeningu neznámých plastů, řešení problémů s QC, ověřování recyklovaných materiálů a kontrole přiřazení píků podložené literaturou.
Běžné chyby
- Považování jednoho izolovaného pásu za důkaz materiálu bez kontroly alespoň jednoho nebo dvou podpůrných píků.
- Ignorování překryvu: více funkčních skupin může přispívat poblíž stejného vlnočtu.
- Přeskakování validace, když mohou aditiva, směsi, oxidace nebo kontaminace zkreslit spektrum.
Rady pro ověření
Pokud přetrvává nejednoznačnost, ověřte hypotézu pomocí DSC, GC-MS nebo TGA, zejména u směsí, degradovaných vzorků a plněných polymerů.
Literatura za těmito přiřazeními
-
spolehlivost 1,0
“659.7 CO32(cid:2) u2 Out-of-plane bending vibration of 883.7 Strong u3 929.6 Very strong Si-O asymmetric stretching vibration of silicate SO42 u3 S-O stretching vibration of 1097 Small shoulder 1114.2”
Theoretical and experimental study of structures and properties of cement paste The nanostructural aspects of C–S–H DOI: 10.1016/j.jpcs.2011.05.001 -
Ring structure spolehlivost 1,0
“Fourier transform infra-red (FTIR) analysis cm-1 confirm 3:Ce3+ cm-1 The FTIR spectra of CaSiO phosphor was recorded in the range 400 - 4000 to the functional groups presentintheobtainedsamples,Fig.2.FTIRspectrashowstrongtransmittancepeaksa”
Dhanu 等 - 2020 - Photoluminescence of mixed phase CaSiO3Ce3+ nanop DOI: 10.1016/j.ijleo.2020.165139 -
Aromatic ring spolehlivost 1,0
“9 is attributed to 1,4-disubstitution of the aromatic ring inpolyaniline.However,therearethreepeaksat884(w),854 (w)cm-1 (m), and 800 on curve 1 in Fig.”
Li 和 Mu - 2005 - The electrochemical activity of sulfonic acid ring DOI: 10.1016/j.synthmet.2004.12.015 -
Carbonate spolehlivost 1,0
“Furthermore, a closer look atthe singlet band 2-1 at 861-864 is probably due to the n ACC.15,32,33 absorption band of carbonate groups from 2-3 singlet reveals a progressive peak shift from 884 (keel), n cm(cid:2)1 887 (needles), to 888 (pl”
Long 等 - 2012 - From synthetic to biogenic Mg-containing calcites DOI: 10.1039/c2cp22453d -
spolehlivost 1,0
“The traces of the organic cm-1 materials from the PVP were at 1535 and 2787 and cm-1, are associated with Si-O stretching at 884, and 889 could be attributed to C-H bending vibrations [47, 48].”
Alibe 等 - 2019 - Effects of polyvinylpyrrolidone on structural and DOI: 10.1007/s10973-018-7874-7 -
Protein spolehlivost 1,0
“cm-1 Increase in absorption at ~884 due to alterations in phosphorylated proteins suggest that more extensive phosphorylation occurs in malignant compared to benign samples.”
ATR-FTIR spectroscopy as adjunct method to the microscopic examination of hematoxylin and eosin-stained tissues in diagnosing lung cancer DOI: 10.1371/journal.pone.0233626 -
spolehlivost 1,0
“ESI-MS molecular-ion peak 884.42, corresponding to H+ + 1H [Zn(L5) ].”
Gusev 等 - 2020 - Synthesis, Photoluminescence and Electrical Study DOI: 10.3390/ma13245698 -
spolehlivost 1,0
“The band at cm-1 δ corresponds to the sAl-O-H mode of boehmite 1,072 cm-1 and the bands at 884, 740, 621, and 479 are attributed Al-O to the bonds of boehmite (Li et al.”
Liu 等 - 2012 - Dechlorinating transformation of propachlor throug DOI: 10.1007/s11368-012-0506-0)
Máte spektrum s tímto pásem?
Nahrajte své FTIR spektrum a získejte plnou interpretační zprávu – přiřazení píků s citacemi literatury, shody s knihovnou a řetězec důkazů s hodnocením spolehlivosti – během několika sekund.