A band near 582 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Szybka odpowiedź
A band near 582 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Możliwe przypisania grup funkcyjnych
| Grupa funkcyjna | Fakty wspierające | Cytowane źródła | Najwyższa wiarygodność |
|---|---|---|---|
| Metal oxygen | 3 | 3 | 1,0 |
| S eq o | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| C-O single bond | 1 | 1 | 0,9 |
Ranking odzwierciedla zgromadzone dowody literaturowe, a nie pojedynczą autorytatywną zasadę. Zawsze potwierdzaj w kontekście swojej próbki.
Możliwe materiały
| Materiał | Piki potwierdzające | Nakładające się grupy | Cytowane źródła |
|---|---|---|---|
| chitosan | 582, 1650, 1655 | Amide | 1 |
| Cellulose | 582, 1735, 1650 | Amide | 1 |
| ZnO | 582, 1400, 3430 | Metal oxygen, Amide | 1 |
| Fe3O4 | 582, 2358, 1673 | Metal oxygen, Amide | 1 |
| iron oxide | 582, 1130, 891 | Metal oxygen | 1 |
| Fe3O4 nanoparticles | 582, 1673, 1470 | Metal oxygen, Amide | 1 |
Materiały są wyświetlane tylko wtedy, gdy ta sama baza literaturowa potwierdza to pasmo i co najmniej jeden dodatkowy charakterystyczny pik.
Logika widma
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 582 cm⁻¹ is usually not enough for material identification by itself.
Zastosowanie w rzeczywistości
Ten typ zapytania jest powszechny w identyfikacji polimerów, przesiewaniu nieznanych tworzyw sztucznych, rozwiązywaniu problemów z kontrolą jakości, weryfikacji materiałów pochodzących z recyklingu oraz przeglądzie przypisania pików wspartym literaturą.
Częste błędy
- Traktowanie jednego izolowanego pasma jako dowodu materiału bez sprawdzenia co najmniej jednego lub dwóch pików wspierających.
- Ignorowanie nakładania się: wiele grup funkcyjnych może przyczyniać się w pobliżu tej samej liczby falowej.
- Pomijanie walidacji, gdy dodatki, mieszanki, utlenianie lub zanieczyszczenia mogą zniekształcić widmo.
Porada dotycząca weryfikacji
Gdy pozostaje niejednoznaczność, zweryfikuj hipotezę za pomocą DSC, GC-MS lub TGA, szczególnie w przypadku mieszanin, zdegradowanych próbek i wypełnionych polimerów.
Literatura stojąca za tymi przypisaniami
-
wiarygodność 1,0
“The peak at 582.2 cm is attributed to the Fe-O bond 4”
ENHANCEMENT OF THERMAL IMAGING BY IRON OXIDE NANOPARTICLE – PRELIMINARY STUDY DOI: 10.1016/j.bcab.2018.12.005 -
Amide wiarygodność 1,0
“The FTIR peaks at 1,678 and 1,582 cm-1 were attributed to amide I and amide II of pNIPAm which was also present in CS spectra.”
Qureshi 等 - 2015 - Ethyl acetate Salix alba leaves extract-loaded chi DOI: 10.1080/09205063.2015.1100843 -
wiarygodność 1,0
“The energy band gap of the NPs was observed toexistintherangeof2.95to3.39eVuponvaryingtheconcentrationofSr2+dopant.Thebroadpeaksat437cm-1and582cm-1 correspond to octahedral (B-) metal stretching (Ni-O) and tetrahedral (A-) metal stretching”
Effect of Sr2+ Ion–Substituted Nickel Ferrite Nanoparticles Prepared by a Simple Microwave Combustion Method DOI: 10.1007/s10948-020-05777-8 -
Phosphate (PO4) wiarygodność 1,0
“Vibrations at 582 593 and 606 are attributed to PO cm-1, the υ4 (PO43-) at 570 and 602 cm-1, υ1 (PO43-) at 962 cm-1, and υ3 (PO43-) at 1051 and 4 vibrations (asymmetric O-P-O bending mode) [46,49-51].”
Gavinho 等 - 2023 - An Eco-Friendly Process to Extract Hydroxyapatite DOI: 10.3390/jfb14050279 -
S eq o wiarygodność 1,0
“capacity Moreover, there is an enlarged band with a slight change at 582 cm-1 in the composite 55 removal beads, indicating the sulfonic acid group, due to the combination of the bands at 633 and”
Potential Application of Innovative Aspergillus terreus/ Sodium Alginate Composite Beads as Eco-Friendly and Sustainable Adsorbents for Alizarin Red S Dye: Isotherms and Kinetics Models DOI: 10.3390/microorganisms11051135 -
wiarygodność 1,0
“cm-1 The bands at 582 may be ascribed to the Zn-O bond [20].”
Toteva 等 - 2021 - Pollutants Sorbent Made of Cotton Fabric Modified DOI: 10.3390/ma14123242 -
C-O single bond wiarygodność 0,9
“explicit assignment”
Barzic 等 - 2022 - Cellulose derivativebarium titanate composites wi DOI: 10.21203/rs.3.rs-467926/v1 -
wiarygodność 0,7
“Pairwise indexed to stretching vibrations.”
Nguyen 等 - 2019 - A Facile Synthesis, Characterization, and Photocat DOI: 10.1155/2019/3428681
Masz widmo z tym pasmem?