What absorbs at 479 cm⁻¹ in an FTIR spectrum?
A band near 479 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Pikavastaus
A band near 479 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mahdolliset funktionaalisten ryhmien määritykset
| Funktionaalinen ryhmä | Tukevat tosiasiat | Viitatut lähteet | Korkein luottamus |
|---|---|---|---|
| Metal oxygen | 3 | 3 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Phosphate (PO4) | 1 | 1 | 1,0 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Carbon dioxide | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
Sijoitus kuvastaa kertyneitä kirjallisuustodisteita, ei yhtä auktoritatiivista sääntöä. Varmista aina suhteessa näytteesi asiayhteyteen.
Mahdolliset materiaalit
| Materiaali | Tukevat huiput | Päällekkäiset ryhmät | Viitatut lähteet |
|---|---|---|---|
| Silica | 479, 1100, 1080 | Silicon-oxygen (Si-O), Alkyl C-H | 1 |
| AgNPs | 479, 1232, 1048 | Alkyl C-H | 1 |
| polystyrene | 479, 1020, 1600 | Alkyl C-H | 1 |
Materiaalit näytetään vain, kun sama kirjallisuuspooli tukee tätä kaistaa ja vähintään yhtä lisäominaisuuspiikkiä.
Spektrilogiikka
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 479 cm⁻¹ is usually not enough for material identification by itself.
Todellinen käyttö
Tällainen kysely on yleinen polymeerien tunnistuksessa, tuntemattomien muovien seulonnassa, laadunvalvonnan vianmäärityksessä, kierrätysmateriaalien varmennuksessa ja kirjallisuuteen perustuvassa piikkien määrityksen tarkastelussa.
Yleiset virheet
- Yksittäisen eristetyn piikin käsittely materiaalin todisteena tarkistamatta ainakin yhtä tai kahta tukevia piikkejä.
- Ohitetaan päällekkäisyys: useat funktionaaliset ryhmät voivat vaikuttaa lähellä samaa aaltolukua.
- Vahvistuksen ohittaminen, kun lisäaineet, seokset, hapettuminen tai kontaminaatio voivat vääristää spektriä.
Varmistusneuvo
Kun epäselvyyttä on jäljellä, vahvista hypoteesi DSC:llä, GC-MS:llä tai TGA:lla, erityisesti seoksille, hajonneille näytteille ja täytetyille polymeereille.
Näiden määritysten taustalla oleva kirjallisuus
-
luottamus 1,0
“Evaluation of leaf aqueous extract and synthesized silver & Mathath Roni Kadarkarai Murugan & Chellasamy Panneerselvam Jayapal Subramaniam Received: 2 November 2012/Accepted: 22 November 2012/Published online: 13 December 2012 # Springer-Ve”
Roni 等 - 2013 - Evaluation of leaf aqueous extract and synthesized DOI: 10.1007/s00436-012-3220-3 -
Carbon dioxide luottamus 1,0
“cm-1, cm-1, cm-1 lowest frequency band, observed at 478.71 474.91 472.12 is assigned to the Fe3+↔O, Co2+↔O octahedral metal stretching of given in Table 2.”
Synthesis, Structural, Optical, Electrical and Mössbauer spectroscopic studies of Co substituted Li0.5Fe2.5O4 DOI: 10.1016/j.jmmm.2016.01.023 -
luottamus 1,0
“RHE, two peaks appeared at 479 the corresponding current on the CV curve increased rapidly, which revealed that Ni oxyhydroxides formed on the reconstructed surface of Ni2P/NF were the real active sites for catalyzing the ammonia decomposit”
Ni(II)/Ni(III) redox couple endows Ni foam-supported Ni2P with excellent capability for direct ammonia oxidation DOI: 10.1016/j.cej.2020.126795 -
Alkyl C-H luottamus 1,0
“CO (stretching) + CCH (stretching) + ring of pyranose (antisymmetric stretching) stretching)/C-O 1255 CO (stretching) + CCH (stretching) + ring of pyranose (antisymmetric (stretching), alcohol, ester, ether, carboxylic acid C-N+ 1078 (symme”
Hayyan 等 - 2015 - Functionalization of graphene using deep eutectic DOI: 10.1186/s11671-015-1004-2 -
luottamus 1,0
“The I 6 cm-1 peak at 479 represents the bending normal vibrations of the Ti-O bond.”
Fabrication of Europium-Doped Barium Titanate/Polystyrene Polymer Nanocomposites Using Ultrasonication-Assisted Method: Structural and Optical Properties DOI: 10.3390/polym14214664 -
Phosphate (PO4) luottamus 1,0
“Based on the listed deconvolution parameters in Table 2, the band at 479 cm-1 is attributed to the bending vibrations of O-P-O in (PO2-)n chain groups [18].”
The Influence of CoO/P2O5 Substitutions on the Structural, Mechanical, and Radiation Shielding of Boro-Phosphate Glasses DOI: 10.3390/ma14216632 -
luottamus 1,0
“cm-1 for Si-O-Si groups (stretching and bending vibrations, respectively), 968 cm-1 for Si-OH groups cm-1 cm-1 813 for Si-O-Si groups (stretching and bending vibrations, respectively), 968 for Si-OH (stretching vibrations) and 479 cm-1 for”
Zdarta 等 - 2017 - Lipase B from Candida antarctica Immobilized on a DOI: 10.3390/catal7010014 -
luottamus 0,9
“Peak at 479 cm-1 assigned to free SiO4.”
Phase Composition of Silica Fume—Portland Cement Systems Formed under Hydrothermal Curing Evaluated by FTIR, XRD, and TGA DOI: 10.3390/ma14112786
Onko sinulla spektri tällä vyöhykkeellä?
Lataa FTIR-spektrisi ja saat täydellisen tulkintaraportin — huippumääritykset kirjallisuusviitteineen, kirjastosumitukset ja luottamusluokitellun todisteketjun — sekunneissa.