What absorbs at 478 cm⁻¹ in an FTIR spectrum?
Una banda cerca de 478 cm⁻¹ puede apuntar a varios grupos funcionales. A continuación se muestran las asignaciones más probables, clasificadas por cuánta evidencia publicada respalda cada una — cada una trazable a literatura (DOI) y validada de forma cruzada con nuestros más de 130,000 espectros de referencia y grafo de conocimiento.
Backed by 8 cited sources
Respuesta rápida
A band near 478 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Posibles asignaciones de grupos funcionales
| Grupo funcional | Hechos de respaldo | Fuentes citadas | Confianza máxima |
|---|---|---|---|
| Metal oxygen | 3 | 3 | 1,0 |
| Silicon-oxygen (Si-O) | 2 | 2 | 1,0 |
| Metal oxo | 2 | 2 | 0,8 |
| Alkyl C-H | 1 | 1 | 1,0 |
| Silanol (Si-OH) | 1 | 1 | 1,0 |
La clasificación refleja la evidencia acumulada de la literatura, no una única regla autorizada. Siempre confirme según el contexto de su muestra.
Materiales posibles
| Material | Picos de apoyo | Grupos superpuestos | Fuentes citadas |
|---|---|---|---|
| calcium carbonate | 478, 3232, 2954 | Alkyl C-H, Silicon-oxygen (Si-O) | 1 |
| SiO2 | 478, 1739, 699 | Silicon-oxygen (Si-O), Alkyl C-H, Metal oxygen | 1 |
| hematite | 478, 1030, 469 | Silicon-oxygen (Si-O), Metal oxygen | 1 |
| goethite | 478, 1470, 696 | Metal oxygen, Silicon-oxygen (Si-O) | 1 |
Los materiales se muestran solo cuando el mismo grupo de literatura respalda esta banda y al menos un pico característico adicional.
Lógica de espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 478 cm⁻¹ is usually not enough for material identification by itself.
Uso en el mundo real
Este tipo de consulta es común en la identificación de polímeros, cribado de plásticos desconocidos, resolución de problemas de control de calidad, verificación de materiales reciclados y revisión de asignación de picos respaldada por la literatura.
Errores comunes
- Tratar una banda aislada como prueba de un material sin verificar al menos uno o dos picos de apoyo.
- Ignorando superposición: múltiples grupos funcionales pueden contribuir cerca del mismo número de onda.
- Omitir la validación cuando los aditivos, las mezclas, la oxidación o la contaminación puedan distorsionar el espectro.
Consejo de verificación
Cuando persista la ambigüedad, valide la hipótesis con DSC, GC-MS o TGA, especialmente para mezclas, muestras degradadas y polímeros rellenos.
Literatura detrás de estas asignaciones
-
confianza 1,0
“Energy dispersive X-ray structures of hematite moved the peak ranges from 478 (EDX) analyses showed a lot of potassium (0.384-4.057%) cm-1 cm-1 to 456 and 574 to 530 (Kosmas et al.”
An integrated toolkit using multiple methods for determining the potential sources of iron and manganese in groundwater: a case study from the lower Kelantan River Basin, Malaysia DOI: 10.1007/s12665-021-09756-7 -
confianza 1,0
“The FTIR spectrum of the mulation with a size that matched the optical microscopy PVA-UHMWPEO/Ag@SiO nanocomposite exhibited several images, where the size of Ag cores was calculated to be 2 cm-1 new absorption peaks, such as 478 of (Si-O)”
Al-Bermany 等 - 2023 - Effect of green synthesis bimetallic Ag@SiO2 core- DOI: 10.1007/s12633-023-02332-7 -
confianza 1,0
“The high-frequency mode at 579 and the peak at 478 can be attributed to cm-1, the Cu-O stretching vibration.”
Structural and UV-blocking properties of carboxymethyl cellulose sodium/CuO nanocomposite films DOI: 10.1038/s41598-023-28032-1 -
Silicon-oxygen (Si-O) confianza 1,0
“In BB5, in addition to the characteristic features of haematite (Fe 2O 3) at 568 and 478 cm-1, the vibrational absorption of quartz (SiO 2), usually occuring in red ochre mixed with haematite, at 797, 781, and 693 cm-1 [49,50], was also App”
The 20th Century Wall Paintings in the Chapel of the Fallen in Parma Cathedral (Italy): Scientific Investigations for a Correct Conservation Project DOI: 10.3390/app13127235 -
Alkyl C-H confianza 1,0
“Small cm-1 bands between 478 and 648 are related to C-H vibration [31].”
Impedance, Electrical Equivalent Circuit (EEC) Modeling, Structural (FTIR and XRD), Dielectric, and Electric Modulus Study of MC-Based Ion-Conducting Solid Polymer Electrolytes DOI: 10.3390/ma15010170 -
Metal oxygen confianza 0,9
“Assigned to Fe-O.”
Hydrothermal synthesis and characterization of amp#x003B1;-Fe2O3 nanoparticles DOI: 10.1016/j.mssp.2012.12.029 -
Metal oxo confianza 0,8
“V-O-V vibrational stretching bond”
Selvakumar 等 - 2022 - Antibacterial Efficacy of Phytosynthesized Multi-M DOI: 10.1155/2022/6506796 -
confianza 0,7
“Band at 478 cm-1 recognized as octahedral metal stretching”
Kiswanto 等 - 2018 - Effect of Zinc on Crystal Structure and Magnetic P DOI: 10.1088/1757-899X/367/1/012001
¿Tiene un espectro con esta banda?
Cargue su espectro FTIR y obtenga un informe de interpretación completo — asignaciones de picos con citas bibliográficas, coincidencias de librerías y una cadena de evidencia con calificación de confianza — en segundos.