What absorbs at 3668 cm⁻¹ in an FTIR spectrum?
A band near 3668 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Quick answer
A band near 3668 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Hydroxyl (O-H) | 4 | 3 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Metal hydroxyl | 1 | 0 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Possible materials
| Материал | Поддерживающие пики | Overlapping groups | Цитируемые источники |
|---|---|---|---|
| kaolinite | 3668, 3696, 693 | Hydroxyl (O-H), Silicon-oxygen (Si-O), Metal hydroxyl | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3668 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Литература, лежащая в основе этих назначений
-
Hydroxyl (O-H) достоверность 1,0
“numbers of 3668 3429 1073 960 840 and 748 The broad band cm-1 cm-1 absorptions at wave number of 3668 dan 3429 show the -OH stretching vibration of sample surface.”
Nizar 等 - 2018 - The Effect of Titanium Tetrahedral Coordination of DOI: 10.1088/1757-899X/335/1/012036 -
Hydroxyl (O-H) достоверность 1,0
“The carbonate compothe structural OH stretching at 3668 and magnesite (Keller & Flynn 2001).”
FTIR and Raman analyses of the Tagish Lake meteorite: Relationship with the aliphatic hydrocarbons observed in the Diffuse Interstellar Medium DOI: 10.1051/0004-6361:20034526 -
Hydroxyl (O-H) достоверность 0,9
“Explicit assignment for kaolinite OH stretching.”
Weng 等 - 2020 - Black carbon enriches short-range-order ferrihydri DOI: 10.1016/j.scitotenv.2020.138195
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.