What absorbs at 3140 cm⁻¹ in an FTIR spectrum?
A band near 3140 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Resposta rápida
A band near 3140 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possíveis atribuições de grupos funcionais
| Grupo funcional | Fatos de suporte | Fontes citadas | Maior confiança |
|---|---|---|---|
| Alkyl C-H | 2 | 2 | 1,0 |
| Silicon-oxygen (Si-O) | 1 | 1 | 1,0 |
| Hydrogen bond | 1 | 1 | 1,0 |
| Aromatic ring | 1 | 1 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Nitrogen heterocycle | 1 | 1 | 1,0 |
| N h | 1 | 1 | 0,7 |
| Water (H2O) | 1 | 0 | 1,0 |
A classificação reflete a evidência acumulada da literatura, não uma única regra autoritária. Sempre confirme com o contexto da sua amostra.
Materiais possíveis
| Material | Picos de suporte | Grupos sobrepostos | Fontes citadas |
|---|---|---|---|
| cellulose | 3140, 1735, 1650 | Alkyl C-H | 1 |
| hemicellulose | 3140, 1730, 897 | Alkyl C-H | 1 |
| GO | 3140, 1720, 1182 | Alkyl C-H | 1 |
| rGO | 3140, 2358, 2930 | Alkyl C-H | 1 |
| PCL | 3140, 1751, 1724 | Alkyl C-H | 1 |
| carrageenan | 3140, 1156, 1100 | Alkyl C-H | 1 |
Os materiais são mostrados apenas quando o mesmo conjunto de literatura suporta esta banda e pelo menos um pico característico adicional.
Lógica do espectro
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3140 cm⁻¹ is usually not enough for material identification by itself.
Uso no mundo real
Este tipo de consulta é comum em identificação de polímeros, triagem de plásticos desconhecidos, solução de problemas de CQ, verificação de materiais reciclados e revisão de atribuição de picos apoiada pela literatura.
Erros comuns
- Tratar uma banda isolada como prova de um material sem verificar pelo menos um ou dois picos de suporte.
- Ignorando sobreposição: vários grupos funcionais podem contribuir próximo ao mesmo número de onda.
- Ignorar a validação quando aditivos, misturas, oxidação ou contaminação podem distorcer o espectro.
Conselho de verificação
Quando a ambiguidade persistir, valide a hipótese com DSC, GC-MS ou TGA, especialmente para misturas, amostras degradadas e polímeros carregados.
Literatura por trás destas atribuições
-
Alkyl C-H confiança 1,0
“In the FTIR spectrum of [DEIm][Br] (Figure 1b), cm-1 C-H the peak at 3140 was due to the bond of imidazole ring,63”
Ionic Liquid Functionalized Metal–Organic Framework ([DEIm][PF6]@MOF-5): Synthesis, Characterization, and Catalytic Application in the Reduction of 4-Nitrophenol DOI: 10.1021/acsomega.2c05808 -
Aromatic ring confiança 1,0
“Louis, MO, USA) were added to the inactivated peaks observed at 3140 are attributed to aromatic C-H cell medium at 45 °C for 1 h and incubated at 37 °C in an stretching vibration bands.”
Erol 等 - 2023 - ZnO-containing nanocomposites produced from Mentha DOI: 10.1007/s10965-023-03461-8 -
Hydrogen bond confiança 1,0
“Bands at 3140 and 3093 could be attributed to the valence vibration of intramolecular hydrogen bond in the EA molecule cm-1 [44].”
Ilic-Stojanovic 等 - 2018 - Thermosensitive hydrogels for modified release of DOI: 10.1080/00914037.2017.1354202 -
Silicon-oxygen (Si-O) confiança 1,0
“7 the FTIR absorption between 3236 and 3250 is due to hydroxyl ions of the clay minerals, cm-1 and the peak at 3140 can be attributed to hydrated ferric oxide.”
Sanchez-Polo 等 - 2019 - An Archaeometric Characterization of Ecuadorian Po DOI: 10.1038/s41598-018-38293-w -
N h confiança 0,7
“Same sentence as above.”
Innovative non-thermal plasma disinfection process inside sealed bags: Assessment of bactericidal and sporicidal effectiveness in regard to current sterilization norms DOI: 10.1371/journal.
Tem um espectro com esta banda?
Carregue seu espectro FTIR e obtenha um relatório de interpretação completo — atribuições de picos com citações da literatura, correspondências de biblioteca e uma cadeia de evidências com nível de confiança — em segundos.