What absorbs at 3078 cm⁻¹ in an FTIR spectrum?
A band near 3078 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 3 cited sources
Quick answer
A band near 3078 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Возможные назначения функциональных групп
| Функциональная группа | Подтверждающие факты | Цитируемые источники | Максимальная достоверность |
|---|---|---|---|
| Alkyl C-H | 2 | 2 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Amide | 1 | 1 | 1,0 |
| Protein | 1 | 1 | 1,0 |
| N h | 1 | 1 | 1,0 |
Ранжирование отражает накопленные литературные данные, а не единственное авторитетное правило. Всегда проверяйте в контексте вашего образца.
Possible materials
| Материал | Поддерживающие пики | Overlapping groups | Цитируемые источники |
|---|---|---|---|
| gold nanoparticles | 3078, 1638, 3252 | Amide, Alkyl C-H | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 3078 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Литература, лежащая в основе этих назначений
-
достоверность 1,0
“cm-1.48,49 1800-1000 and Control skin showed characteristic verified with the results extracted from elemental analysis (MPcm-1 chemical peaks at 3078, 2929, and 2856 corresponding to AES in the AC and the DC), as well as the amount of gold”
High-Sensitivity Permeation Analysis of Ultrasmall Nanoparticles Across the Skin by Positron Emission Tomography DOI: 10.1021/acs.bioconjchem.1c00017 -
Alkyl C-H достоверность 1,0
“f 4 1 70 45 trace cm-1 -C-H for aromatic stretching, 2879.78 FTIR: 3077.78 cm-1 -C-H for aliphatic stretching, 1682.17 and 1626.54 cm-1 cm-1 °C, After that, for 3 h at 70 the same model reaction was -N�CHAr-C�Cfor stretching, 1517.76 for cm”
Manjare 等 - 2023 - Microwave-Assisted Rapid and Green Synthesis of Sc DOI: 10.1021/acsomega.2c05187 -
Alkyl C-H достоверность 1,0
“LLM confirmed rule peak-group candidate”
Optical Absorption and Visible Photoluminescence from Thin Films of Silicon Phthalocyanine Derivatives DOI: 10.3390/ma7096585
Есть спектр с этой полосой?
Загрузите свой FTIR-спектр и получите полный отчет об интерпретации — назначение пиков с цитированием литературы, совпадения с библиотекой и цепочку доказательств с оценкой достоверности — за секунды.