What absorbs at 3013 cm⁻¹ in an FTIR spectrum?
A band near 3013 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Caktime të mundshme të grupeve funksionale
| Grup funksional | Fakte mbështetëse | Burimet e cituara | Besueshmëri e lartë |
|---|---|---|---|
| Alkene (C=C) | 2 | 2 | 1,0 |
| Alkyl C-H | 2 | 2 | 1,0 |
| Protein | 1 | 1 | 1,0 |
Renditja pasqyron provat e grumbulluara të literaturës, jo një rregull të vetëm autoritar. Gjithmonë konfirmoni në kontekstin e mostrës suaj.
Literatura pas këtyre caktimeve
-
Alkyl C-H besueshmëri 1,0
“cm-1 The investigation in the region 3050-2800 indicates cm-1 band ~ 3013 is because of the HC=CH stretching”
Spectral profile index changes as biomarker of toxicity in Catla catla (Hamilton, 1822) edible fish studied using FTIR and principle component analysis DOI: 10.1007/s42452-020-3001-z -
Alkene (C=C) besueshmëri 1,0
“LLM confirmed rule peak-group candidate”
Kinetic and Stoichiometric Modeling-Based Analysis of Docosahexaenoic Acid (DHA) Production Potential by Crypthecodinium cohnii from Glycerol, Glucose and Ethanol DOI: 10.3390/md20020115 -
Alkyl C-H besueshmëri 1,0
“(B) Lipid unsaturation levels, 2 3 (C) olefinic band and CH bands (ratio I 3013/ I 2851+2922);”
FTIR Spectroscopy as a Tool to Study Age-Related Changes in Cardiac and Skeletal Muscle of Female C57BL/6J Mice DOI: 10.3390/molecules26216410 -
Alkene (C=C) besueshmëri 1,0
“Peak intensity for olefinic band (~3013 cm-1olefinic band, C=CH stretching) and CH sum of the saturated lipid bands (~2922 2”
Fourier-Transform Infrared Spectroscopy as a Discriminatory Tool for Myotonic Dystrophy Type 1 Metabolism: A Pilot Study DOI: 10.3390/ijerph18073800 -
Protein besueshmëri 1,0
“3013 The positive bands in PC-1 are assigned to proteins and the negative bands are assigned to lipids, fatty acids and triglycerides.”
Monitoring Radiotherapeutic Response in Prostate Cancer Patients Using High Throughput FTIR Spectroscopy of Liquid Biopsies DOI: 10.3390/cancers11070925
Keni një spektër me këtë brez?
Ngarkoni spektrin tuaj FTIR dhe merrni një raport të plotë interpretimi — caktim i pikut me citime literaturë, përputhje biblioteke dhe një zinxhir provash të vlerësuar me besueshmëri — në sekonda.
Interpreto spektrin tim