What absorbs at 2991 cm⁻¹ in an FTIR spectrum?
A band near 2991 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Schnelle Antwort
A band near 2991 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Mögliche Funktionsgruppenzuweisungen
| Funktionelle Gruppe | Unterstützende Fakten | Zitierte Quellen | Höchstes Vertrauen |
|---|---|---|---|
| Alkyl C-H | 6 | 6 | 1,0 |
| Methyl | 3 | 3 | 1,0 |
Das Ranking spiegelt die gesammelte Literatur Evidenz wider, nicht eine einzelne maßgebliche Regel. Bestätigen Sie immer anhand Ihres Probenkontexts.
Mögliche Materialien
| Material | Unterstützende Peaks | Überlappende Gruppen | Zitierte Quellen |
|---|---|---|---|
| TiO | 2991, 1730, 1699 | Alkyl C-H | 1 |
| rGO | 2991, 2358, 2930 | Alkyl C-H | 1 |
| PLA | 2991, 1650, 1073 | Alkyl C-H | 1 |
| PEG | 2991, 1650, 1342 | Alkyl C-H | 1 |
| PLLA | 2991, 1182, 921 | Alkyl C-H, Methyl | 1 |
Materialien werden nur angezeigt, wenn derselbe Literaturpool diese Bande und mindestens einen weiteren charakteristischen Peak unterstützt.
Spektrumslogik
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2991 cm⁻¹ is usually not enough for material identification by itself.
Praktische Anwendung
Diese Art von Abfrage ist üblich bei der Polymeridentifikation, dem Screening unbekannter Kunststoffe, der Fehlersuche in der Qualitätskontrolle, der Verifizierung von Recyclingmaterial und der literaturgestützten Überprüfung der Peakzuordnung.
Häufige Fehler
- Behandlung einer isolierten Bande als Beweis für ein Material, ohne mindestens einen oder zwei unterstützende Peaks zu überprüfen.
- Überlappung ignorieren: Mehrere funktionelle Gruppen können nahe der gleichen Wellenzahl beitragen.
- Überspringen der Validierung, wenn Additive, Mischungen, Oxidation oder Verunreinigungen das Spektrum verfälschen können.
Beratung zur Verifizierung
Wenn weiterhin Mehrdeutigkeit besteht, validieren Sie die Hypothese mit DSC, GC-MS oder TGA, insbesondere bei Mischungen, degradierten Proben und gefüllten Polymeren.
Literatur hinter diesen Zuweisungen
-
Alkyl C-H Vertrauen 1,0
“The two cm-1 bands at 2991 and 2948 can be attributed to the C-H bond stretching vibrations of the -CH and”
Awad 等 - 2020 - Experimental Investigation of Methyl Methacrylate DOI: 10.3390/ma13245793 -
Alkyl C-H Vertrauen 1,0
“LLM confirmed rule peak-group candidate”
Structural and Surface Compatibility Study of Modified Electrospun Poly(ε-caprolactone) (PCL) Composites for Skin Tissue Engineering DOI: 10.1208/s12249-016-0500-8 -
Alkyl C-H Vertrauen 1,0
“The characteristic band at 2991 cm-1 to 2976 cm-1 cm-1 cm-1 (C=C 2976 corresponds to C-H stretching vibrations, 1652 skeletal vibration), 1521”
Complex Permittivity and Electromagnetic Interference Shielding Effectiveness of OPEFB Fiber-Polylactic Acid Filled with Reduced Graphene Oxide DOI: 10.3390/ma13204602 -
Alkyl C-H Vertrauen 1,0
“The asymmetric and symmetric C-H stretching (St.) cm1 cm1, of the methyl groups were attributed to the transmission bands at 2991 and 2943 respectively.”
Ragab - 2022 - Improved Physical, thermal, and conductivity stren DOI: 10.21203/rs.3.rs-1514992/v1 -
Alkyl C-H Vertrauen 1,0
“The bands at 2991 and 2868 which were attributed to various C-H stretching vibrations, had opposite signs on the PC2 and PC3 loading curves.”
Ex Vivo Vibration Spectroscopic Analysis of Colorectal Polyps for the Early Diagnosis of Colorectal Carcinoma DOI: 10.3390/diagnostics11112048 -
Methyl Vertrauen 0,9
“Explicit assignment: CH3 asymmetric stretching”
Differentiation in MALDI-TOF MS and FTIR spectra between two pathovars of Xanthomonas oryzae DOI: 10.1016/j.saa.2014.06.056 -
Methyl Vertrauen 0,9
“Explicit assignment: 'absorption peak around 2991 ... stretching vibration peak of CH3'”
Li 等 - 2020 - Effect of molecular weight of polyethylene glycol DOI: 10.1039/d0ra08699a -
Alkyl C-H Vertrauen 0,8
“Text: 'strong peak at 2991.3 cm-1 (Q is assigned as the center branch) ... R(2) transition of our 5ν C-H'”
Perez-Delgado 和 Manzanares - 2010 - Cavity Ring Down and Fourier Transform Infrared Sp DOI: 10.1021/jp105382p
Haben Sie ein Spektrum mit dieser Bande?
Laden Sie Ihr FTIR-Spektrum hoch und erhalten Sie in Sekunden einen vollständigen Interpretationsbericht – Peakzuweisungen mit Literaturzitaten, Bibliotheksübereinstimmungen und einer vertrauensbewerteten Evidenzkette.