What absorbs at 2977 cm⁻¹ in an FTIR spectrum?
A band near 2977 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 8 cited sources
Quick answer
A band near 2977 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| Alkyl C-H | 10 | 10 | 1,0 |
| Ring structure | 1 | 1 | 1,0 |
| Carbohydrate | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Possible materials
| Materiale | Picchi di supporto | Overlapping groups | Fonti citate |
|---|---|---|---|
| cellulose | 2977, 1735, 1650 | Alkyl C-H, Carbohydrate | 1 |
| hemicellulose | 2977, 1730, 897 | Alkyl C-H | 1 |
| lignin | 2977, 1035, 1510 | Alkyl C-H | 1 |
| biomass | 2977, 1082, 1282 | Alkyl C-H | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 2977 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
Letteratura dietro queste assegnazioni
-
Alkyl C-H affidabilità 1,0
“cm-1 The peaks that appear at 2977 and 2898 were 3.3 FTIR-ATR spectroscopy characterization associated with the stretching of the C-H bond.”
Mondragon-Cortez 等 - 2022 - Application of Fourier transform infrared spectros DOI: 10.24275/rmiq/Alim2806 -
Alkyl C-H affidabilità 1,0
“These waveband peak results 2977 is attributed to the C-H vibrations of the may indicate a reduction in sugar, which would and -CH moiety vibrations in alkyl group and -CH 2”
Use of thermal imaging and Fourier transform infrared spectroscopy for the pre-symptomatic detection of cucumber downy mildew DOI: 10.1007/s10658-019-01775-2 -
Alkyl C-H affidabilità 1,0
“LLM confirmed rule peak-group candidate”
Ajibade 和 Mbese - 2014 - Synthesis and Characterization of Metal Sulfides N DOI: 10.1155/2014/752394 -
Alkyl C-H affidabilità 1,0
“Bond (vibration) Degradation product 2977 C-H (asymmetric stretching) C xH y”
Hejna 等 - 2017 - Performance properties of rigid polyurethane-polyi DOI: 10.1515/epoly-2017-0012 -
Alkyl C-H affidabilità 1,0
“at 2977 and 2924 cm-1 due to stretching vibration of C-H (the bands at 2994, 2977, 2924, 2904 and 2890 would be due to”
Oliveira 等 - 2016 - FTIR analysis and quantification of phenols and fl DOI: 10.1590/S1517-707620160003.0072 -
Alkyl C-H affidabilità 1,0
“peaks at 2977 and 2931 were cm-1 assigned to C-H stretching vibration within the ring;”
In Vitro Interaction of Doxorubicin-Loaded Silk Sericin Nanocarriers with MCF-7 Breast Cancer Cells Leads to DNA Damage DOI: 10.3390/polym13132047 -
Alkyl C-H affidabilità 1,0
“The absorptions at 2977 and 2929, cm-1 2900 are allocated to symmetric and anti-symmetric vibration of CH in the alkyl chain in EO, tween 20, 2”
Nanoliposomes containing three essential oils from the Artemisia genus as effective larvicides against Aedes aegypti and Anopheles stephensi DOI: 10.1038/s41598-023-38284-6 -
Alkyl C-H affidabilità 1,0
“1026 C-O stretching 2977 C-H stretching 2875 C-H stretching”
Zhuang 等 - 2020 - Observation of Potential Contaminants in Processed DOI: 10.3390/app10124345
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.