What absorbs at 1996 cm⁻¹ in an FTIR spectrum?
A band near 1996 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 4 cited sources
Quick answer
A band near 1996 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
可能的官能团归属
| 官能团 | 支持性事实 | 引用来源 | 最高置信度 |
|---|---|---|---|
| Hydroxyl (O-H) | 2 | 2 | 1.0 |
| Amide | 2 | 2 | 1.0 |
| Adsorbed carbon monoxide | 1 | 0 | 1.0 |
排名反映了累积的文献证据,而非单一的权威规则。请始终对照您的样品背景进行确认。
Possible materials
| 材料 | 支持峰 | Overlapping groups | 引用来源 |
|---|---|---|---|
| gelatin | 1996, 1652, 3300 | Amide, Hydroxyl (O-H) | 1 |
| collagen | 1996, 1408, 1660 | Amide | 1 |
Materials are shown only when the same literature pool supports this band and at least one additional characteristic peak.
Spectrum logic
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1996 cm⁻¹ is usually not enough for material identification by itself.
Real-world usage
This type of query is common in polymer identification, unknown plastic screening, QC troubleshooting, recycled-material verification, and literature-backed peak assignment review.
Common mistakes
- Treating one isolated band as proof of a material without checking at least one or two supporting peaks.
- Ignoring overlap: multiple functional groups can contribute near the same wavenumber.
- Skipping validation when additives, blends, oxidation, or contamination may distort the spectrum.
Verification advice
When ambiguity remains, validate the hypothesis with DSC, GC-MS, or TGA, especially for blends, degraded samples, and filled polymers.
这些分配背后的文献
-
Hydroxyl (O-H) 置信度 1.0
“Kohlstedt w orthopyroxene-saturated boninitic melts exhibit hydroxyl absorption le 1996;”
Matveev 等 - 2005 - FTIR spectrum of phenocryst olivine as an indicato DOI: 10.1093/petrology/egh090 -
Amide 置信度 1.0
“It has been used to study collagen number of amide III peak (Jakobsen et al., 1983), band crosslinking (Paschalis et al., 2001), denaturation (Friess broadening and shift of amide I peak to lower wave & Lee, 1996), thermal self assembly (Ja”
Muyonga 等 - 2004 - Fourier transform infrared (FTIR) spectroscopic st DOI: 10.1016/j.foodchem.2003.09.038 -
Amide 置信度 1.0
“(1996), "the main amide I absorption in infarctedtissueisshiftedfrom1650to1628cm-1,ashiftindicative of either a structural rearrangement of the existing tissue proteins or the expression of a new set of proteins with different struc-”
Vidal 和 Mello - 2011 - Collagen type I amide I band infrared spectroscopy DOI: 10.1016/j.micron.2010.09.010 -
Hydroxyl (O-H) 置信度 1.0
“KOCH-MüLLER AND RHEDE: IR ABSORPTION COEFFICIENTS FOR NAMS line-the values plot above and below the curve of Libowitzky increases and thus the intensity of the corresponding OH band and Rossman (1996).”
Koch-Mueller 和 Rhede - 2010 - IR absorption coefficients for water in nominally DOI: 10.2138/am.2010.3358
是否有此波段的光谱?
上传您的FTIR光谱,几秒钟内即可获得完整的解读报告——包含带文献引用的峰分配、库匹配和带有置信度评级的证据链。