What absorbs at 1805 cm⁻¹ in an FTIR spectrum?
A band near 1805 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Possibili assegnazioni di gruppi funzionali
| Gruppo funzionale | Fatti di supporto | Fonti citate | Affidabilità massima |
|---|---|---|---|
| N-O bond | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Carbonate | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
La classifica riflette le prove bibliografiche accumulate, non una singola regola autorevole. Conferma sempre nel contesto del tuo campione.
Letteratura dietro queste assegnazioni
-
affidabilità 1,0
“In particular, addition of 14 cm-1 O to NO slightly increases the amount of Pd(II)-NO complex with ν at ~1865 whereas 15 2 NO 16 cm-1, the low frequency ν band at 1805 assigned to Pd(I)-NO, decreases in intensity.”
Molecular Level Understanding of How Oxygen and Carbon Monoxide Improve NOx Storage in Palladium/SSZ-13 Passive NOx Adsorbers: The Role of NO+ and Pd(II)(CO)(NO) Species DOI: 10.1021/acs.jpcc.8b01007 -
Carbonyl (C=O) affidabilità 1,0
“a consistent amount of ethylene carbonate (EC) is obtained, as cm-1 testified by the presence of a doublet of bands at 1805 and cm-1 1774 that can be easily ascribed to the combined carbonyl stretching modes of the ethylene carbonate.”
Dani 等 - 2015 - Design of high surface area poly(ionic liquid)s to DOI: 10.1039/c5ta00272a -
N-O bond affidabilità 1,0
“In this case a cm(cid:2)1 new band appears at 1805 corresponds to gas phase NO.”
Diaz Consul 等 - 2008 - NO reduction with CO on alumina-modified silica-su DOI: 10.1016/j.apcata.2008.01.022 -
Hydroxyl (O-H) affidabilità 1,0
“1409-1460 C = O (Asymetric stretching) O-H (Bending) 1805 Vibrations of carbonate ions 2512 C = O from calcite”
da Silva 和 Wiebeck - 2022 - ATR-FTIR Spectroscopy Combined with Chemometric Me DOI: 10.21203/rs.3.rs-905784/v1 -
affidabilità 0,9
“band around ~1805 cm-1 for Pd/SSZ-13 belonged to Pd(I)-NO”
The superior hydrothermal stability of Pd/SSZ-39 in low temperature passive NOx adsorption (PNA) and methane combustion DOI: 10.1016/j.jcat.2010.07.031.
Hai uno spettro con questa banda?
Carica il tuo spettro FTIR e ottieni un report di interpretazione completo — assegnazioni di picchi con citazioni bibliografiche, corrispondenze con librerie e una catena di prove con valutazione di affidabilità — in secondi.
Interpreta il mio spettro