What absorbs at 1805 cm⁻¹ in an FTIR spectrum?
A band near 1805 cm⁻¹ can point to several functional groups. Below are the most likely assignments, ranked by how much published evidence supports each — every one traceable to literature (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.
Backed by 5 cited sources
Rychlá odpověď
A band near 1805 cm⁻¹ is usually interpreted by checking which functional groups repeatedly co-occur there in the literature, then confirming at least one or two additional peaks in the same sample. This page ranks those assignments by accumulated evidence rather than by a single fixed textbook rule.
Možná přiřazení funkčních skupin
| Funkční skupina | Podpůrná fakta | Citované zdroje | Nejvyšší spolehlivost |
|---|---|---|---|
| N-O bond | 2 | 2 | 1,0 |
| Hydroxyl (O-H) | 1 | 1 | 1,0 |
| Carbonate | 1 | 1 | 1,0 |
| Alkene (C=C) | 1 | 1 | 1,0 |
| Carbonyl (C=O) | 1 | 1 | 1,0 |
Pořadí odráží nahromaděné literární důkazy, nikoli jediné autoritativní pravidlo. Vždy potvrďte v kontextu vašeho vzorku.
Možné materiály
| Materiál | Podpůrné píky | Překrývající se skupiny | Citované zdroje |
|---|---|---|---|
| polyethylene | 1805, 1737, 1720 | Hydroxyl (O-H) | 1 |
| HDPE | 1805, 1369, 1216 | Hydroxyl (O-H) | 1 |
Materiály jsou zobrazeny pouze tehdy, když stejný literární soubor podporuje tento pás a alespoň jeden další charakteristický pík.
Logika spektra
This band becomes meaningful only when read with its neighboring peaks. In practice, analysts first look at the assignments above, then check whether the same sample also shows other peaks expected for the same structural motif. A lone band near 1805 cm⁻¹ is usually not enough for material identification by itself.
Reálné použití
Tento typ dotazu je běžný při identifikaci polymerů, screeningu neznámých plastů, řešení problémů s QC, ověřování recyklovaných materiálů a kontrole přiřazení píků podložené literaturou.
Běžné chyby
- Považování jednoho izolovaného pásu za důkaz materiálu bez kontroly alespoň jednoho nebo dvou podpůrných píků.
- Ignorování překryvu: více funkčních skupin může přispívat poblíž stejného vlnočtu.
- Přeskakování validace, když mohou aditiva, směsi, oxidace nebo kontaminace zkreslit spektrum.
Rady pro ověření
Pokud přetrvává nejednoznačnost, ověřte hypotézu pomocí DSC, GC-MS nebo TGA, zejména u směsí, degradovaných vzorků a plněných polymerů.
Literatura za těmito přiřazeními
-
spolehlivost 1,0
“In particular, addition of 14 cm-1 O to NO slightly increases the amount of Pd(II)-NO complex with ν at ~1865 whereas 15 2 NO 16 cm-1, the low frequency ν band at 1805 assigned to Pd(I)-NO, decreases in intensity.”
Molecular Level Understanding of How Oxygen and Carbon Monoxide Improve NOx Storage in Palladium/SSZ-13 Passive NOx Adsorbers: The Role of NO+ and Pd(II)(CO)(NO) Species DOI: 10.1021/acs.jpcc.8b01007 -
Carbonyl (C=O) spolehlivost 1,0
“a consistent amount of ethylene carbonate (EC) is obtained, as cm-1 testified by the presence of a doublet of bands at 1805 and cm-1 1774 that can be easily ascribed to the combined carbonyl stretching modes of the ethylene carbonate.”
Dani 等 - 2015 - Design of high surface area poly(ionic liquid)s to DOI: 10.1039/c5ta00272a -
N-O bond spolehlivost 1,0
“In this case a cm(cid:2)1 new band appears at 1805 corresponds to gas phase NO.”
Diaz Consul 等 - 2008 - NO reduction with CO on alumina-modified silica-su DOI: 10.1016/j.apcata.2008.01.022 -
Hydroxyl (O-H) spolehlivost 1,0
“1409-1460 C = O (Asymetric stretching) O-H (Bending) 1805 Vibrations of carbonate ions 2512 C = O from calcite”
da Silva 和 Wiebeck - 2022 - ATR-FTIR Spectroscopy Combined with Chemometric Me DOI: 10.21203/rs.3.rs-905784/v1 -
spolehlivost 0,9
“band around ~1805 cm-1 for Pd/SSZ-13 belonged to Pd(I)-NO”
The superior hydrothermal stability of Pd/SSZ-39 in low temperature passive NOx adsorption (PNA) and methane combustion DOI: 10.1016/j.jcat.2010.07.031.
Máte spektrum s tímto pásem?
Nahrajte své FTIR spektrum a získejte plnou interpretační zprávu – přiřazení píků s citacemi literatury, shody s knihovnou a řetězec důkazů s hodnocením spolehlivosti – během několika sekund.