FTIR FUNCTIONAL GROUP

Silicon carbon — FTIR absorption peaks and assignments

These are the characteristic FTIR wavenumbers where Silicon carbon tends to absorb, compiled from published literature and ranked by supporting evidence. Each assignment is traceable to a source (DOI) and cross-validated against our 130,000+ reference spectra and knowledge graph.

Backed by 8 cited sources

Characteristic FTIR peaks for Silicon carbon

Wavenumber (cm⁻¹) Supporting facts Cited sources Top confidence
1260 6 6 1.0
800 5 4 0.9
1255 3 3 1.0
840 2 2 0.9
791 2 2 0.9
1270 2 2 0.9
1265 2 2 0.8
1261 1 1 1.0
1263 1 1 1.0
809 1 1 1.0
2855 1 1 0.95
1464 1 1 0.95
1258 1 1 0.9
819 1 1 0.9
1256 1 1 0.9
794 1 1 0.9
760 1 1 0.9
820 1 1 0.9
1410 1 1 0.9
680 1 1 0.9
1300 1 1 0.9
857 1 1 0.9
950 1 1 0.9
789 1 1 0.9
845 1 1 0.9
1400 1 1 0.9
2900 1 1 0.9
790 1 1 0.8
605 1 1 0.7
630 1 1 0.7

Showing the 30 best-supported peaks of 39 total for Silicon carbon.

Literature behind these assignments

See Silicon carbon in your own spectrum

Upload your FTIR spectrum and get a full interpretation report — peak assignments with literature citations, library matches, and a confidence-rated evidence chain — in seconds.

Interpret my spectrum
Submit Request Form